background image

4

  

CHARGING STAGES

 

Soft Charge (Level 1)

 – When batteries suffer an over-discharge, the controller will softly 

ramp the battery voltage up to 10V.

 

Bulk Charge (Level 2)

 – Maximum current charging until batteries rise to Absorption level

  Absorption Charge (Level 3)

 – Constant voltage charging and battery is over 85%.

 

Equalization Charge* (Level 4)

 – Only for WET battery or Calcium battery type, when the 

battery is deeply drained below 10V, it will automatically run this stage to bring the internal cells 
as an equal states and fully complement the loss of capacity.(Gel and AGM battery do not run 
Equalization charge)

  Float Charge (Level 5)

 – Battery is fully charged and maintained at a safe level. A fully 

charged battery has a voltage of more than 13.6 Volts.

  LED OPERATION

Level 1

Level 2

Level 3

Level 4*

Level 5

 

The 3 LED’s indicate the charging  

Fault 

Charge 

Full 

status and Fault connection 

Red 

Blue 

Green

 

Solar Power Present –  

ON 

Slow Flash 

Slow Flash

 

No battery connected 

 

Battery reversed 

ON 

Fast Flash 

Fast Flash

 

Solar panel reversed 

OFF 

OFF 

OFF

 

Soft start charging 

OFF 

Slow Flash 

OFF

 

Bulk, Absorption  

OFF ON OFF

 

Equalisation charging

 

Float charging 

OFF 

OFF 

ON

 

Solar panel weak 

Slow Flash 

OFF 

OFF

 

At night no charge 

OFF 

OFF 

OFF

 

Slow flash = 1 Hz flash, Fast flash = 3 Hz flash

Summary of Contents for SPM80K

Page 1: ...fied person if the unit requires repairing FEATURE OVERVIEW SOLAR PANEL Compact and Powerful Monocrystalline solar panels are manufactured from a solar cell that is cast from silicon These cells are m...

Page 2: ...ill stop charging when the battery is full and will automatically start charging the battery as required This process will also reduce water loss and help prevent the battery from drying out Discharge...

Page 3: ...f the solar charge controller this Dip switch is used for presetting your battery type Please refer to Figure 1 1 to make DIP switch setting for the proper battery chemical the factory default setting...

Page 4: ...he loss of capacity Gel and AGM battery do not run Equalization charge Float Charge Level 5 Battery is fully charged and maintained at a safe level A fully charged battery has a voltage of more than 1...

Page 5: ...or Absorption charging timer timed out 4 Hour 2 7 Equalization charging active Only for WET or Calcium battery Battery voltage discharged to less than 10 0 2 VDC Automatic equalizing charging periodi...

Page 6: ...D Indication page 4 for further details of charging status STEP 3 Secure the solar panel to the ground Secure by pushing the legs into the ground For greater set up stability secure the panel to the g...

Page 7: ...e my flat battery how long will it take A The SPM80K will charge a flat battery above 9V 250 900CCA Automotive with a charge time of 7 35Hrs The SPM120K will charge a flat battery above 9V 250 1200CCA...

Page 8: ...purchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair...

Reviews: