Installation Guide                                              

DISCLAIMER 

PROJOY assumes no responsibility for any loss, in particular for circuit damage, resulting from any violation of 

the specifications recommended and referred to in this specification. PROJOY assumes no responsibility for the 

damage of the product caused by the maintenance, improper use, wrong installation or wrong system design of 

the product by non-designated personnel. 

 

SAFETY INSTRUCTIONS 

1.

 

PEFS is an electrical product that should be installed by a suitable person who meets local regulations. 

2.

 

When modifying and existing installation, isolate the inverter from the PV array by turning OFF the DC 

isolator / switch disconnect or turn OFF the inverter and the AC switch. 

3.

 

Incorrect connections to the PEFS-PL may cause failure. 

 

CAUTIONS 

If the inverter and pv module connectors are not compatible with PEFS connectors, forced connections are 

unsafe and may cause operational problems. 

For the mechanical compatibility of the module / converter and PEFS, use the same connectors from the same 

manufacturer on both the PEFS and modules, or obtain verification that the connectors to be used are 

compatible. 

Do not drill through the PEFS-PL product, as this will damage the PEFS-PL component and make it impossible for 

PEFS-PL to work. 

 

INTRODUCTION 

PEFS-PL is Rapid Shutdown Equipment for connection to PV panel arrays in order to achieve compliance to NEC 

690.12 requirements of 2017. 

1. When the PEFS-PL system detects that the voltage of the 24V remote control bus is normal, and the 

temperature sensor inside the PFS-PL system judges that the temperature of the control panel is lower than 85

 

and higher than -30

, the switch unit is closed.

 

2. When the PEFS-PL system detects that  the voltage of the 24V remote control bus is abnormal, or the 

temperature sensor in the PFS-PL system judges that the temperature of the control panel is higher than 85

  or 

lower than -30

, the switch unit is disconnected.

 

Summary of Contents for PEFS-PL Series

Page 1: ......

Page 2: ...nnections are unsafe and may cause operational problems For the mechanical compatibility of the module converter and PEFS use the same connectors from the same manufacturer on both the PEFS and modules or obtain verification that the connectors to be used are compatible Do not drill through the PEFS PL product as this will damage the PEFS PL component and make it impossible for PEFS PL to work INT...

Page 3: ...it should be mounted within the array boundary of the two panels where the two panels are no greater than 1 foot 30cm apart from each other The installation locations and modes of PFS PL and PEFS ESW are shown below By placing the PEFS PL in position against the underside of the PV panel or the surface where the temperature needs to be sensed Once mounted ensure that the PEFS PL is secure Mounting...

Page 4: ...t off and the emergency switch fails PFS PL will be turned off and the pv module output will be disconnected The Emergency Rapid Shutdown Switch Unit PEFS ESW can be conveniently located anywhere for emergency access and is supplied with an internal 24VDC power supply to interface with the PEFS PL units Remove the PEFS ESW cover taking care not to damage the switch or power supply contained within...

Page 5: ...e 24VDC pin 2 negative 0VDC Do not remove the wire connection between the PEFS ESW power supply positive pole and the switch Connect the AMP socket female of PFS PL to the AMP plug male of PEFS ESW MULTIPLE INSTALLATIONS One PEFS PL will control two solar panels and by series connection of the PEFS multiple solar panel pairs can be connected to form a greater capacity system The diagram below illu...

Page 6: ...sabling the PV module s output Should the detected temperature then drop back to below 85 C the PEFS PL will re engage the PV module s output 2 Manual shutdown Upon the user operating the red push button switch located in the Emergency Switch Enclosure the PEFS PL performs a Rapid Shutdown disabling the PV array output 3 AC Supply Cut Off Shutdown Should there be a necessity by the emergency servi...

Page 7: ...l Cable Length 1200 mm Panel Cable Length 120 mm String Cable Length 1200 mm Standard UL 1741 NEC 2017 690 12 Type PEFS ESW Input Voltage 100 240V AC Rated input current 200mA Vi 115VAC 135mA Vi 230VAC Rated Output Voltage 24V DC Controlled fast shutdown number 20 With Lock Optional Dimensions 125 125 75 mm Ambient Operating Temperature 30 55 Communication GPRS Optional TROUBLESHOOTING Problem Pos...

Page 8: ...S PL input connections Incorrect PEFS PL polarity connection Check PV array Positive goes to PEFS PL Positive and PV array Negative goes to PEFS PL Negative No PEFS PL output Replace PEFS PL PV Inverter input 0V No DC isolator if fitted input Check PEFS PL output connections Check DC inputs to isolator DC Isolator if fitted OFF Turn DC Isolator ON String voltage too low Incorrect PEFS PL polarity ...