Where reference has been made above to the use of the PEFS-PL80S-11/PEFS-PL80S-21 as the source of supply of the 
24VDC, it can also be considered that power can be supplied to the RSD units by an alternative suitably rated UL Approved 
24VDC Class II power supply (AC/DC or DC/DC types). This power supply unit should be used in conjunction with a shutdown 
initiator that ensures disconnection of the 24VDC supply upon operation, and for the PEFS-PL80S-11/PEFS-PL80S-21 the 
appropriate in-line fuse must also be installed in the 24VDC line.As the supply of these parts are outside the scope of Projoy 
we recommend that the device’s instructions of use are fully understood and the necessary appropriate precautions made 
when using such parts; and that the correct 24V/0V polarity connections are made as indicated in this installation guide.

One RSD PEFS-PL80S-11/PEFS-PL80S-21 will control two solar panels and by series connection of the FireRaptor, multiple 
solar panel pairs can be  connected to form a greater capacity system. The diagram below illustrates a typical example of a 
FireRaptor protected installation using eight  solar panels and four PEFS-PL80S-11/PEFS-PL80S-21 FireRaptors.

MULTIPLE INSTALLATIONS

If it is found that the product cannot be output�
1)  Please check whether the 24V power supply is normal. After the 24V power supply is restored, the product can output 
normally.

5   Trouble shooting

www.projoy-electric.com

RSD PEFS-PL80S

N≤60

N≤60

String

DC 24V

Power out