background image

Please read the safety instructions carefully before using or 

maintaining the equipment 
●Never expose the equipment directly in the sun.
●Never store the equipment at dusty humidity and high

temperature (over 40

) environment.

●Battery replacement should follow specification; otherwise, it may

damage the equipment.

●Never disassemble the equipment by yourself. Maintenance or

repair should be by professional person.

●Please remove the battery from both transmitter and receiver

when storing equipment to avoid battery liquid leaked.

●Never detect live power cord by this equipment; otherwise, it may

damage equipment or injure person.

●Never connect to any equipment when thunderstorms are likely,

this may cause personal shocked.

Overview   

MT-7059 LCD Multifunction Cable Tester combines transmitter, 
receiver and remote unit. The large LCD display design with multi 
testing function, fast test result display, and user friendly design 
features easy operation and user convenience. Ideal for long 
distance wire tracing, communication line status checking, weak 
circuits testing, weak distribution system installation and 
maintenance. Widely used in telecommunications systems, 
computer networks, network monitoring and other metal wire lines 
and other fields. 

www.sycelectronica.com.ar

Summary of Contents for HT-7059

Page 1: ...HT 7059 LCD Multifunction Cable Tester User s Manual 1st Edition 2018 2018 Copyright by Prokit s Industries Co Ltd www sycelectronica com ar...

Page 2: ...detect live power cord by this equipment otherwise it may damage equipment or injure person Never connect to any equipment when thunderstorms are likely this may cause personal shocked Overview MT 705...

Page 3: ...d other test socket without complex conversion Power on off and backlight display on off selectable switching function Auxiliary lighting function Different sound indicated for different circuit statu...

Page 4: ...AC 60V DC 42V Low battery display LCD 6 5V Battery type DC 9 0VNEDA 1604 6F22 DC9V 1 Alkaline battery recommended Dimension LxWxD 185X80X32mm Receiver Frequency 225kHz The max working current 70mA Ea...

Page 5: ...ion Instructions for product Install DC 9V battery to transmitter then press ON OFF button it is power on with a long sound LCD will showed TEST then auto started wire mapping test if the cable is not...

Page 6: ...ess LIGHT to turn on backlight when you test in dark environment Several test results as follows may occur Test Result1 Short SHORT If cable or connector connected situation is short transmitter LCD w...

Page 7: ...3 6 line of RJ45 cable is open Test Result 5 Crossover or miss wire LCD will show as following figure with two short sounds The figure indicates that 3 6 line of RJ45 cable is crossover Test Result 6...

Page 8: ...cable BNC cable USB cable USB cable with shielding USB cable without shielding Hunting test Plug in the target cable RJ45 RJ11 USB BNC 1394 that wanted to find press ON OFF button power on with a long...

Page 9: ...n the battery is low LCD will show flash icon Please replace battery 2 LCD backlight function Press the LIGHT key on transmitter panel LCD backlight will light up and around 10 seconds lights off auto...

Page 10: ...nsmitter is on SCAN function If above two ways can t solve problem Instrument is damaged please send it back to us for repair Perform test with telecom switching equipment can t receive the tone signa...