7

GLOBE

- 3 -  FUNCTIONS  AND SETTINGS

3.1 OPERATION

To turn on the GLOBE proceed as follows:

•  Connect the power cable to the controller bar of the GLOBE.

•  Connect the supplied main cable to a socket (100-240V~/50-60Hz).

•  Switch on the GLOBE by the switch on the rear panel of the controller bar.

Shortly after that the GLOBE is ready for operation. To switch off, disconnect the mains plug from the 

socket.

3.2 BASIC

The GLOBE has a LED display and  4 button used to access the control panel functions and manage them 

(fig.3).

MENU

UP

DOWN

ENTER

Used to access the menu or 
to return a previous menu 
option

Navigates downwards through 
the menu list and increases 
the numeric value when in a 
function

Navigates upwards through 
the menu list and decreases 
the numeric value when in 
a function

Used to select and store the 
current menu or confirm the 
current function value or 
option within a menu

Fig.3 - Functions of the buttons

Summary of Contents for GLOBE

Page 1: ...MANUALE UTENTE USER MANUAL GLOBE IT EN LED GLOBES EFFECTS ...

Page 2: ...rziale per propri scopi commerciali è vietata Al fine di migliorare la qualità dei prodotti la Music Lights S r l si riserva la facoltà di modificare in qualunque momento e senza preavviso le specifiche menzionate nel presente manuale di istruzioni Tutte le revisioni e gli aggiornamenti sono disponibili nella sezione Manuali sul sito www musiclights it ...

Page 3: ...crizione 1 2 Specifiche tecniche 1 3 Elementi di comando e di collegamento 2 Installazione 2 1 Montaggio 3 Funzioni e impostazioni 3 1 Funzionamento 3 2 Impostazione base 3 3 Struttura menu 3 4 Modalità automatica 3 5 Modalità Master Slave 3 6 Collegamento 3 7 Modalità DMX 3 8 Connessione ARTNET 3 9 Canali DMX 4 Manutenzione 4 1 Manutenzione e pulizia unità 4 4 5 5 6 8 9 9 10 10 10 11 11 12 13 14 ...

Page 4: ...dità in luoghi soggetti a vibrazioni o a possibili urti in luoghi a temperatura superiore ai 40 C Evitare che nell unità penetrino liquidi infiammabili acqua o oggetti metallici Non smontare e non apportare modifiche all unità Tutti gli interventi devono essere sempre e solo effettuati da personale tecnico qualificato Rivolgersi al più vicino centro di assistenza tecnica autorizzato Se si desidera...

Page 5: ... fissa La confezione di GLOBE include 2pz hanging bar 10pz strighe da 3mt con 15 sfere borsa per il trasporto 1 2 SPECIFICHE TECNICHE Sorgente luminosa e ottica 150 globi sferici con LED SMD RGB Sorgente LED in 1 pixel 2x SMD5050 RGB FullColor Pixel pitch 200 mm Diametro sfere 50mm Angolo di proiezione 360 LED life span 50 000h Funzionamento ed elettronica Alimentazione e controllo tramite driver ...

Page 6: ...le attraverso connessioni XLR3p e cavo 4 poli Assorbimento medio 60W ogni hanging bar Peso 4 kg Dimensioni LxA 2000x3000 mm Fig 1 Pannello Posteriore 1 3 ELEMENTI DI COMANDO E COLLEGAMENTI POWER OUT DMX OUT POWER IN DMX IN 5 4 3 1 2 7 8 9 10 11 2 1 6 1 2 3 ...

Page 7: ...sso e gestione delle diverse funzioni 5 AGGANCIO CONNETTORI 6 GLOBO LED 7 POWER OUT output alimentazione per connessione di più unità in serie 8 DMX OUT XLR a 3 poli 1 massa 2 DMX 3 DMX 9 DMX IN XLR a 3 poli 1 massa 2 DMX 3 DMX 10 INTERRUTTORE ALIMENTAZIONE ON OFF 11 POWER IN PowerCON IN per il collegamento ad una presa di rete 100 240V 50 60Hz tramite il cavo di rete in dotazione ...

Page 8: ...vere una stabilità sufficiente e supportare almeno 10 volte il peso del dispositivo Inoltre assicurarsi di rispettare tutte le avvertenze in materia di sicurezza Aprire e montare il GLOBE su una superficie piana Sollevare e assicurare il GLOBE su una struttura truss attraverso l utilizzo di ganci appositi Fig 2 GANCIO ALISCAFF GANCIO ALISCAFF ...

Page 9: ...pina dalla presa di rete 3 2 IMPOSTAZIONE BASE Il GLOBE dispone di un display LED e 4 pulsanti per accesso alle funzioni del pannello di controllo fig 3 Fig 3 Funzione dei tasti MENU UP DOWN ENTER Per scorrere il menu principale o tornare ad una opzione del menu precedente Per scorrere attraverso le diverse funzioni in ordine discendente o aumentare il valore della funzione stessa Per scorrere att...

Page 10: ... velocità di riproduzione dello show automatico procedere come segue Premere il tasto MENU fino a quando sul display non appare Speed Premere il tasto UP DOWN per selezionare la velocità desiderata da 1 a 9 Premere il tasto ENTER per confermare 3 5 MODALITÀ MASTER SLAVE Questa modalità consente di collegare in serie più unità GLOBE La prima unità sarà impostata come ma ster e le altre funzionerann...

Page 11: ...La tabella a pagina 14 indica la modalità di funzionamento e i relativi valori DMX Per impostare l indirizzo DMX premere il tasto MENU fino a quando sul display non appare DMX CH Premere il tasto UP DOWN per selezionare DMX 12 CH quindi premere ENTER per confermare Premere il tasto MENU fino a quando sul display non appare DMX Address Premere il tasto UP DOWN per selezionare il valore desiderato 0...

Page 12: ...e si desidera 150CH 225CH 300CH 375CH 450CH quindi premere ENTER per confermare Premere il tasto MENU fino a quando sul display non appare DMX Address Premere il tasto UP DOWN per selezionare il valore desiderato 001 512 Premere il tasto ENTER per confermare l impostazione Impostare tutte le barre di controllo con lo stesso indirizzo DMX Una volta terminata la procedura è possibile controllare tut...

Page 13: ...ODE FUNCTION 12 Ch 1 DISPLAY SELECT 2 SUB DIMMER 3 RED COLOR 4 GREEN COLOR 5 BLUE COLOR 6 STROBE 7 SPEED 8 PROGRAM GROUP 1 P1 P10 9 PROGRAM GROUP 2 P11 P20 10 PROGRAM GROUP 3 P21 P30 11 PROGRAM GROUP 4 P31 P40 12 PROGRAM GROUP 5 P41 P50 ...

Page 14: ...one dell unità e le sue parti dovrebbero essere assicurate saldamen te e non dovrebbero essere corrose Alloggiamenti elementi di fissaggio e di installazione soffitto truss sospensioni dovrebbero essere totalmente esenti da qualsiasi deformazione I cavi di alimentazione devono essere in condizione impeccabile e dovrebbero essere sostituiti imme diatamente nel momento in cui anche un piccolo proble...

Page 15: ......

Page 16: ...r by any means for any commercial use In order to improve the quality of products Music Lights S r l reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice All revisions and updates are available in the manuals section on site www musiclights it ...

Page 17: ...scription 1 2 Technical specifications 1 3 Operating elements and connections 2 Installation 2 1 Mounting 3 Functions and settings 3 1 Operation 3 2 Basic 3 3 Menu structure 3 4 Automatic mode 3 5 Master Slave mode 3 6 Linking 3 7 DMX configuration 3 8 ARTNET connection 3 9 DMX control 4 Maintenance 4 1 Maintenance and cleaning the unit 2 2 3 3 4 6 7 7 8 8 8 9 9 10 11 12 ...

Page 18: ... in places with a temperature of over 40 C Make certain that no inflammable liquids water or metal objects enter the fixture Do not dismantle or modify the fixture All work must always be carried out by qualified technical personnel Contact the nearest sales point for an inspection or contact the manufacturer directly If the unit is to be put out of operation definitively take it to a local recycl...

Page 19: ...d any type of fixed installation The packaging of GLOBE includes 2pcs hanging bar 10pcs 3mt string with 15 spheres each nylon bag for transport 1 2 TECHNICAL SPECIFICATIONS Light source and optics 150 globes with RGB SMD LEDs inside LED source in 1 pixel 2pcs SMD5050 RGB FullColor Pixel pitch 200 mm Spheres diameter 50mm Projection angle 360 LED life span 50 000 h Electronics and features Power su...

Page 20: ...CTIONS Rear Panel Fig 1 POWER OUT DMX OUT POWER IN DMX IN 5 4 3 1 2 7 8 9 10 11 2 1 6 1 2 3 IN OUT wiring signal connections through XLR3p and 4 pole cable Average power consumption 60W each hanging bar Weight 4 kg Dimensions WxH 2000x3000 mm ...

Page 21: ...control panel functions and manage them 5 CONNECTION HOLE for male connectors 6 LED GLOBE 7 POWER OUT power output for connection of multiple units in series 8 DMX OUT 3 pole XLR 1 ground 2 DMX 3 DMX 9 DMX IN 3 pole XLR 1 ground 2 DMX 3 DMX 10 POWER SWITCH ON OFF 11 POWER IN PowerCON IN for connection to a socket 100 240V 50 60Hz via the supplied mains cable ...

Page 22: ...rt a weight of 10 times of the unit s weight When carrying out any installation always comply scrupulously with all the regulations particularly re garding safety currently in force in the country in which the fixture s being used Unfold and assemble the GLOBE on a flat surface Lift and hang up the GLOBE on a structure truss through the use of special clamps CLAMP CLAMP ...

Page 23: ...connect the mains plug from the socket 3 2 BASIC The GLOBE has a LED display and 4 button used to access the control panel functions and manage them fig 3 MENU UP DOWN ENTER Used to access the menu or to return a previous menu option Navigates downwards through the menu list and increases the numeric value when in a function Navigates upwards through the menu list and decreases the numeric value w...

Page 24: ...ust the auto program speed proceed as follows Press the button MENU so many times until the display shows Speed Press the UP DOWN button to select the desired speed 1 9 Press the ENTER button to confirm 3 5 MASTER SLAVE MODE This mode will allow you to link up the units together Choose a unit to function as the Master The unit must be the first unit in line other units will work as slave with the ...

Page 25: ...e display shows DMX CH Press the button UP DOWN to select DMX 12 CH then press ENTER to confirm Press the button MENU so many times until the display shows DMX Address Press the button UP DOWN to select the desired value 001 512 Press the button ENTER to confirm the setting Set all driver bar to same DMX address Press the button MENU so many times until the display shows Mix Display Press the butt...

Page 26: ...n 150CH 225CH 300CH 375CH 450CH through the buttons UP DOWN then press ENTER to confirm Press the button MENU so many times until the display shows DMX Address Press the button UP DOWN to select the desired value 001 512 Press the button ENTER to confirm the setting Set all driver bar to same DMX address Once the procedure is finished you can control all the driver bars connected by MADRIX Softwar...

Page 27: ... MODE FUNCTION 12 Ch 1 DISPLAY SELECT 2 SUB DIMMER 3 RED COLOR 4 GREEN COLOR 5 BLUE COLOR 6 STROBE 7 SPEED 8 PROGRAM GROUP 1 P1 P10 9 PROGRAM GROUP 2 P11 P20 10 PROGRAM GROUP 3 P21 P30 11 PROGRAM GROUP 4 P31 P40 12 PROGRAM GROUP 5 P41 P50 ...

Page 28: ... All screws used for installing the device and any of its parts should be tightly fastened and should not be corroded Housings fixations and installation spots ceiling trusses suspensions should be totally free from any deformation The main cables must be in impeccable condition and should be replaced immediately even when a small problem is detected ...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...ietà della Music Lights S r l PROLIGHTS TRIBE is a brand of Music Lights S r l company MUSIC LIGHTS S r l Via Appia km 136 200 04020 Itri LT ITALY Phone 39 0771 72190 Fax 39 0771 721955 www musiclights it email info musiclights it ISO 9001 2008 Certified Company ...