17
H150UFC
- 3 - MAINTENANCE
3.1 CLEANING AND STORAGE
Do not allow the fog liquid to become contaminated. Always replace the caps on the fog liquid container
and the fog machine liquid tank immediately after filling. Cleaning your fog machine regularly can help
you to reduce the frequency of parts replacement and the cost of maintenance. After every 40 hours of
continuous operation, it is recommended to use distilled water to clean the heater as per following steps:
The recommended cleaning regimen is as follows:
1. Fill proper distilled water into a clean tank and connect the fluid tube of the fog machine to the tank.
2. Run the unit in a well-ventilated area until the tank is almost empty.
3. Use dry cloth to wipe the fog machine. Cleaning is now complete.
4. Refill with fog liquid. Run the machine briefly to clear any remaining liquid from the pump and heater.
NOTE - All fog machines are prone to clogging due to the thick consistency of fog liquid and the high
temperature at which it vaporizes. However, a properly maintained fog machine should provide years of
reliable use.
Clean with a dry cloth only. Store dry.
If the fog machine is not in use, please clean it before storage. Store the fog machine in a dry and cool
place. At least operate the fog machine once a month. A test-run consisits of warming-up the machine
followed by a few minutes of fog emission.
3.2 BREAKER RESET
This guide lists the main steps you must take to reset the breaker:
1. Disconnect the unit from the power supply.
2. Reset the breaker to the ON position.
3. Connect the unit to the mains and turn on to test it.
NOTE - Replace the breaker only with a breaker of the same type and with the same characteristics:
230V = 9A 250V.
3.3 TROUBLE SHOOTING
This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the
steps below in sequence until a solution is found. Once the unit operates properly, do not carry out follow-
ing steps. If the problem persists, refer servicing to a qualified technician.
Power connected but no fog is emitted:
1. Check the power supply. Plug the unit into grounded electric power supply socket with proper voltage.
2. Check the fog fluid in the tank.
3. Check your controller connection.
4. Disconnect fog machine from electric power supply. Replace fuse with one of the same type.