background image

7

LUMIPAR 18QPRO

- 3 -  FUNCTIONS  AND SETTINGS

3.1 OPERATION

Connect the supplied main cable to a socket (100-240 VAC-50/60 Hz). Then the unit is ready for operation 

and can be operated via a DMX controller or it independently performs its show program in succession. 

To switch off, disconnect the mains plug from the socket. For a more convenient operation it is recom-

mended to connect the unit to a socket which can be switched on and off via a light switch.

 

3.2 BASIC

Access control panel functions using the four panel buttons located directly underneath the LCD Display 

(fig.3).

MENU

ENTER

UP

DOWN

Used to access the menu or 
to return a previous menu 
option

Used to select and store the 
current menu or confirm the 
current function value or 
option within a menu

Navigates downwards through 
the menu list and increases 
the numeric value when in a 
function

Navigates upwards through 
the menu list and decreases 
the numeric value when in 
a function

Fig.3

MENU UP DOWN ENTER

Summary of Contents for LUMIAPAR18QPRO

Page 1: ...EN IT Manuale Utente User Manual LUMIPAR18QPRO SUPER SLIM LED PAR ...

Page 2: ...rziale per propri scopi commerciali è vietata Al fine di migliorare la qualità dei prodotti la Music Lights S r l si riserva la facoltà di modificare in qualunque momento e senza preavviso le specifiche menzionate nel presente manuale di istruzioni Tutte le revisioni e gli aggiornamenti sono disponibili nella sezione Manuali sul sito www musiclights it ...

Page 3: ...1 Funzionamento 3 2 Impostazione base 3 3 Struttura menu 3 4 Modalità Auto Show 3 5 Modalità Static 3 6 Modalità Master Slave 3 7 Collegamento 3 8 Configurazione canale DMX 3 9 Modalità DMX 3 10 Collegamenti della linea DMX 3 11 Costruzione del terminatore DMX 3 12 Tabella canali DMX 3 13 Funzioni dispositivo 3 14 Informazioni sul dispositivo 3 15 Calibrazione bianco 4 Manutenzione 4 1 Manutenzion...

Page 4: ...e ai 45 C Evitare che nell unità penetrino liquidi infiammabili acqua o oggetti metallici Non smontare e non apportare modifiche all unità Tutti gli interventi devono essere sempre e solo effettuati da personale tecnico qualificato Rivolgersi al più vicino centro di assistenza tecnica autorizzato Se si desidera eliminare il dispositivo definitivamente consegnarlo per lo smaltimento ad un istituzio...

Page 5: ...e delle Condizioni Generali di Garanzia Si prega dopo l acquisto di procedere alla registrazione del prodotto sul sito www musiclights it In alternativa il prodotto può essere registrato compilando e inviando il modulo riportato alla fine del manuale A tutti gli effetti la validità della garanzia è avallata unicamente dalla presentazione del certificato di garanzia Music Lights constata tramite ve...

Page 6: ...o ed elettronica Pannello di controllo tramite display LCD Diverse configurazioni DMX disponibili 4 5 10 canali per controllo professionale o semplificato 4 canali RGBW 5 canali Dimmer RGBW 10 canali Dimmer RGBW strobe macro auto auto speed dimmer curve Regolazione curva dimmer 3 configurazioni selezionabili Modalità Automatica programmi automatici preimpostati con regolazione velocità Modalità co...

Page 7: ...play e 4 pulsanti per accesso e gestione delle diverse funzioni 6 POWER IN connettore di potenza Neutrik per il collegamento ad una presa di rete 100 240V 50 60Hz tramite il cavo rete in dotazione 7 POWER OUT connettore di potenza Neutrik output alimentazione per connessione di più unità in serie 8 PORTAFUSIBILE sostituire un fusibile difettoso solo con uno dello stesso tipo 9 SAFETY EYE per l agg...

Page 8: ...bilità sufficiente e supportare almeno 10 volte il peso dell unità Inoltre assicurarsi di rispettare tutte le avvertenze in materia di sicurezza Fissare il proiettore attraverso l apposita staffa 1 ad una collocazione idonea È assolutamente necessario assicurare il proiettore contro la caduta utilizzando un cavo di sicurezza in particolare collegare il cavo in un punto adatto in modo che la caduta...

Page 9: ...ta da un interruttore 3 2 IMPOSTAZIONE BASE Il proiettore LUMIPAR18QPRO dispone di un LCD display e 4 pulsanti per accesso alle funzioni del pannello di controllo fig 3 Fig 3 MENU UP DOWN ENTER MENU UP DOWN ENTER Per scorrere il menu principale o tornare ad una opzione del menu precedente Per scorrere attraverso le diverse funzioni in ordine discendente o aumentare il valore della funzione stessa ...

Page 10: ... White BW Blue White RG W Red Green White R BW Red Blue White GBW Green Blue White RGBW Red Green Blue White Manu C Manual C Combine red green blue and white to make a custom color R 255 G 255 B 255 W 255 3 Dim Mode Dim Mode DIM 1 Off Default On DIM 1 DIM 1 Dimmer speed fast 0 8 s DIM 2 DIM 2 Dimmer speed middle 1 6 s DIM 3 DIM 3 Dimmer speed slow 2 4 s 4 Back Lite Back Lite On On Default On 10 s ...

Page 11: ...e 0 9999H 0 H Default 0H Version V1 1 6 Address Address DMX address 001 512 001 512 7 Channel Channel DMX Channel 4Ch 4Ch 5Ch 10Ch 8 M S Mode M S Mode Master Master Slave 9 White Balance Value Balance R 255 R 125 255 G 255 G 125 255 B 255 B 125 255 ...

Page 12: ...re impostati attraverso la seguente procedura Per entrare nella modalità static premere il tasto MENU ripetutamente fino a quando sul display non appare STATIC quindi premere ENTER per confermare Utilizzare i tasti UP DOWN per selezionare la funzione preset color FIXT C quindi premere ENTER per confermare Selezionare il preset color desiderato R G B W GB RB RG RGB RW GW BW RGW RBW GBW RGBW attrave...

Page 13: ...are il valore desiderato 001 512 tenere premuto invece il tasto UP DOWN per lo scorrimento veloce Premere il tasto ENTER per confermare l impostazione Per poter comandare il LUMIPAR18QPRO con un unità di comando luce occorre impostare l indirizzo di start DMX per il primo canale DMX Se per esempio sull unità di comando è previsto l indirizzo 33 per comandare la funzione del primo canale DMX si dev...

Page 14: ... Collegare quindi l uscita DMX con l ingresso DMX della successiva unità l uscita di quest ultima con l ingresso di quella successiva e via dicendo finchè tutte le unità sono collegate formando una catena Per installazioni in cui il cavo di segnale deve percorrere lunghe distanze è consigliato inserire sull ulti ma unità una terminazione DMX 3 11 COSTRUZIONE DEL TERMINATORE DMX La terminazione evi...

Page 15: ...070 071 090 091 110 111 130 131 150 151 170 171 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 7 STROBE No Function 1 20Hz 000 010 011 255 8 AUTO No Function Show 1 Auto program 1 Show 2 Auto program 2 Show 3 Auto program 3 Show 4 Auto program 4 Show 5 Auto program 5 000 051 052 101 102 152 153 203 204 254 255 CH5 CH Function in Ch 5 mode Value 1 MASTER...

Page 16: ...te di verificare il corretto funzionamento dell unità Per avviare il test procedere nel seguente modo Premere il tasto MENU ripetutamente fino a quando sul display non compare INFO quindi premere ENTER per confermare Selezionare attraverso i tasti UP DOWN la funzione AUTOTEST Per confermare e dare l avvio al test automatico premere il tasto ENTER FixHours Permette di visualizzare le ore di funzion...

Page 17: ...o a quando sul display non appare WHITE BALANCE quindi premere il tasto ENTER Selezionare il canale R G e B attraverso i tasti UP DOWN Per confermare premere il tasto ENTER Impostare i valori 125 255 attraverso i tasti UP DOWN quindi premere il tasto ENTER PremereiltastoMENUpertornareindietrooattenderealcunisecondiperusciredalmenudiimpostazione ...

Page 18: ...iavite rimuovere il portafusibile dalla sua sede e il fusibile bruciato dal suo supporto sostituire il fusibile con uno identico per tipologia e valore 3 Inserire il portafusibile al suo posto e ricollegare l alimentazione 4 3 RISOLUZIONE DEI PROBLEMI Fig 8 Anomalie Possibili cause Controlli e rimedi Il proiettore non illumina Mancanza di alimentazione di rete Dimmer impostato a 0 Tutti i colori i...

Page 19: ......

Page 20: ...r by any means for any commercial use In order to improve the quality of products Music Lights S r l reserves the right to modify the characteristics stated in this instruction manual at any time and without prior notice All revisions and updates are available in the manuals section on site www musiclights it ...

Page 21: ... 1 Mounting 3 Functions and settings 3 1 Operation 3 2 Basic 3 3 Menu structure 3 4 Auto Show mode 3 5 Static mode 3 6 Master Slave mode 3 7 Linking 3 8 DMX configuration 3 9 DMX mode 3 10 Connection of the DMX line 3 11 Construction of the DMX termination 3 12 DMX control 3 13 Fixture settings 3 14 Fixure information 3 15 White calibration 4 Maintenance 4 1 Maintenance and cleaning the unit 4 2 F...

Page 22: ...le liquids water or metal objects enter the fixture Do not dismantle or modify the fixture All work must always be carried out by qualified technical personnel Contact the nearest sales point for an inspection or contact the manufacturer directly If the unit is to be put out of operation definitively take it to a local recycling plant for a disposal which is not harmful to the environment Warnings...

Page 23: ...site www musiclights it Please remember to register the piece of equipment soon after you purchase it logging on www musiclights it The product can be also registered filling in and sending the form available on your guarantee certificate For all purposes the va lidity of the guarantee is endorsed solely on presentation of the guarantee certificate Music Lights will verify the validity of the clai...

Page 24: ...onics and features User panel through LED display Several DMX selectable configurations 4 5 10 channels for advanced or basic controlling 4 channels RGBW 5 channels Dimmer RGBW 10 channels Dimmer RGBW strobe macro auto auto speed dimmer curve Dimmer curve setting 3 selectable configurations Auto mode built in programs with execution speed adjustment Static colour mode selection of static colour Ma...

Page 25: ...ANEL with display and 4 button used to access the control panel functions and manage them 6 POWER IN Neutrik connector for connection to a socket 100 240V 50 60Hz via the supplied mains cable 7 POWER OUT Neutrik connector power output for connection of multiple units in series 8 MAIN FUSE HOLDER replace a burnt out fuse by one of the same type only 9 SAFETY EYE to attach safety cable 1 2 8 3 6 4 7...

Page 26: ...ys comply scrupulously with all the regulations particularly re garding safety currently in force in the country in which the fixture s being used Install the projector at a suitable location by means of the mounting bracket 1 Always additionally secure the projector with the safety rope from falling down For this purpose fas ten the safety rope at a suitable position so that the maximum fall of t...

Page 27: ... unit to a socket which can be switched on and off via a light switch 3 2 BASIC Access control panel functions using the four panel buttons located directly underneath the LCD Display fig 3 MENU ENTER UP DOWN Used to access the menu or to return a previous menu option Used to select and store the current menu or confirm the current function value or option within a menu Navigates downwards through...

Page 28: ... White BW Blue White RG W Red Green White R BW Red Blue White GBW Green Blue White RGBW Red Green Blue White Manu C Manual C Combine red green blue and white to make a custom color R 255 G 255 B 255 W 255 3 Dim Mode Dim Mode DIM 1 Off Default On DIM 1 DIM 1 Dimmer speed fast 0 8 s DIM 2 DIM 2 Dimmer speed middle 1 6 s DIM 3 DIM 3 Dimmer speed slow 2 4 s 4 Back Lite Back Lite On On Default On 10 s ...

Page 29: ...e 0 9999H 0 H Default 0H Version V1 1 6 Address Address DMX address 001 512 001 512 7 Channel Channel DMX Channel 4Ch 4Ch 5Ch 10Ch 8 M S Mode M S Mode Master Master Slave 9 White Balance Value Balance R 255 R 125 255 G 255 G 125 255 B 255 B 125 255 ...

Page 30: ...hases via the control panel on the back of the fixture To enable the static mode press MENU repeatedly until STATIC shows on the display Through the button UP DOWN select FIXT C Select the desired preset color R G B W GB RB RG RGB RW GW BW RGW RBW GBW RGBW through the buttons UP DOWN Press ENTER button to confirm Select the desired preset color using the button UP DOWN and press ENTER to confirm 3...

Page 31: ...the MENU button to go back or to meet the waiting time to exit the setup menu To able to operate the LUMIPAR18QPRO with a light controller adjust the DMX start address for the first a DMX channel If e g address 33 on the controller is provided for controlling the function of the first DMX channel adjust the start address 33 on the LUMIPAR18QPRO The other functions of the light effect panel are the...

Page 32: ...of the first unit Connect the DMX output to the DMX input of the following unit Connect again the output to the input of the following unit until all the units are connected in chain When the signal cable has to run longer distance is recommended to insert a DMX termination on the last unit DMX OUTPUT XLR socket DMX INPUT XLR plug Pin1 GND Shield Pin2 Negative Pin3 Positive Fig 6 3 11 CONSTRUCTION...

Page 33: ...071 090 091 110 111 130 131 150 151 170 171 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 7 STROBE No Function 1 20Hz 000 010 011 255 8 AUTO No Function Show 1 Auto program 1 Show 2 Auto program 2 Show 3 Auto program 3 Show 4 Auto program 4 Show 5 Auto program 5 000 051 052 101 102 152 153 203 204 254 255 CH5 CH Function in Ch 5 mode Value 1 MASTER DIM...

Page 34: ... 14 FIXTURE INFORMATION Auto Test Allow checking the proper functioning of the unit Start the automatic test in the following way Press the button MENU so many times until shows INFO then press the ENTER button to confirm Using the button UP DOWN to select AUTOTEST To confirm and start the automatic test press the ENTER button FixHours Show the fixture working hours Press the button MENU so many t...

Page 35: ...s the button MENU so many times until shows WHITE BALANCE and press the button ENTER to con firm Select R G and B through the buttons UP DOWN Press MENU button to confirm Set the value 125 255 through the buttons UP DOWN Press the MENU button to go back or to meet the waiting time to exit from the setup menu automati cally ...

Page 36: ... penetrate the unit and cause damage to it 4 2 FUSE REPLACEMENT 1 Remove the safety cap by a screwdriver 2 Replace the blown fuse with a fuse of the exact same type and rating 3 Install the safety cap and reconnect power 4 3 TROUBLESHOOTING Fig 8 Problems Possible causes Checks and remedies Fixture does not light up No mains supply Dimmer fader set to 0 All color faders set to 0 Faulty LED Faulty ...

Page 37: ...chi conseguenti sono a carico del possessore dell apparecchio A tutti gli effetti la validità della garanzia è avallata unicamente dalla presentazione del certificato di garanzia The guarantee covers the unit in compliance with existing regulations You can find the full version of the General Guarantee Conditions on our web site www musiclights it Abstract General Guarantee Conditions Please remem...

Page 38: ...date Data acquisto FORM TO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE PROV ZIP CODE C A P MODEL MODELLO SERIAL N SERIE N Purchased by Acquistato da SURNAME COGNOME Dealer s stamp and signature Timbro e firma del Rivenditore NAME NOME ADDRESS VIA N CITY CITTà Purchasing date Data acquisto PROV ZIP CODE C A P ...

Page 39: ......

Page 40: ...39 0771 721955 www musiclights it info musiclights it Music Lights S r l entertainment technologies ISO 9001 2008 Certified Company 2013 Music Lights S r l PROLIGHTS è un brand di proprietà della Music Lights S r l PROLIGHTS is a brand of Music Lights S r l company ...

Reviews: