CAUTION:

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled 
indoor area free of conductive contaminants. (See the specifications for the acceptable 
temperature and humidity range.)
To reduce the risk of overheating the UPS, 

DO NOT 

cover the UPS' cooling vents and avoid 

exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as 
space heaters or furnaces.

DO NOT 

attach non-computer-related items, such as medical equipment, life-support 

equipment, microwave ovens, or vacuum cleaners to UPS.

DO NOT 

plug the UPS input into its own output.

DO NOT 

allow liquids or any foreign object to enter the UPS. 

DO NOT 

place beverages or any 

other liquid-containing vessels on or near the unit. 
In the event of an emergency, press the OFF button and disconnect the power cord from the 
AC power supply to properly disable the UPS.

DO NOT 

attach a power strip or surge suppressor to the UPS.

If the UPS is with metal chassis, for safety purpose, grounding is a must during UPS 
installation in order to reduce leakage current below 3.5mA.
Attention hazardous through electric shock. Also with disconnection of this unit from the 
mains, hazardous voltage still may be accessible through supply from battery. The battery 
supply should be therefore disconnected in the plus and minus pole at the quick connectors 
of the battery when maintenance or service work inside the UPS is necessary.
Servicing of batteries should be performed or supervised by personnel knowledgeable of 
batteries and the required precautions.  Keep unauthorized personnel away from batteries. 
When replacing the batteries, use the same number and type of batteries.
Internal 1 block of 12VDC VRLA (Valve-Regulated Lead–Acid) battery.

DO NOT 

dispose of batteries in a fire. The battery may explode. 

DO NOT 

open or mutilate the 

battery or batteries. Released electrolyte is harmful to the skin and eyes.
Unplug the UPS prior to cleaning and 

DO NOT 

use liquid or spray detergent.

A battery can present a risk of electric shock and high short circuit current. The following 
precaution should be observed before replacing batteries:

1.

2.

3.

4.
5.

6.

7.
8.

9.

10.

11.
12.
13.

14.
15.

i.
ii.
iii.
iv.
v.

Remove watches, rings, or other metal objects.
Use tools with insulated handles.
Wear rubber gloves and boots.
Do not lay tools or metal parts on top of batteries.
Disconnect charging source prior to connecting or disconnecting batteries terminal.

1. Important Safety Warning 

Summary of Contents for PRO850SFCU

Page 1: ...s or need further information pertaining to the device please visit our website at www prolink2u com All specifications are subject to the manufacturer s configuration at the time of shipping and may...

Page 2: ...ric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and...

Page 3: ...e optional 4 Items 2 1 3 optional 4 optional BEFORE GETTING STARTED This document is designed to aid you to get started with the device If you experience problems following these guides or need furthe...

Page 4: ...5 1 2 Legend LED Indication 1 Power Switch 2 USB port 3 4 Power AC Input 5 RJ11 Ports Modem Fax Protection 6 Backup Outlets Fault LED Red lighting Battery mode LED Yellow flashing AC mode LED Green li...

Page 5: ...0 cm to avoid interference DO NOT operate the UPS where the temperature and humidity is outside the specific limits Please check the specs for the limitations 6 Hours Connect to Utility and Charging P...

Page 6: ...itical load Battery voltage is too low Charge the UPS at least 6 hours Battery defect It might be due to high temperature operation environment or improper operation to battery Replace the battery wit...

Page 7: ...230VAC 12 14 230VAC 10 50Hz 1 Battery Mode Simulated Sine Wave Battery Mode Sine Wave AC Mode Typical 2 6ms 12V 10AH 1pc 8 30 mins depending on load 2 4 hours recover to 90 capacity Yes Line Mode and...

Page 8: ...awah 3 5mA Perhatian tersengat listrik sangat berbahaya Juga dengan melepaskan unit ini dari sumber listrik tegangan berbahaya masih tersimpan pada baterai Kabel baterai juga harus dilepas disaat mela...

Page 9: ...t kabel USB optional 4 Items 2 1 3 optional 4 optional BEFORE GETTING STARTED This document is designed to aid you to get started with the device If you experience problems following these guides or n...

Page 10: ...sar Legend Indikator LED 1 Power Switch 2 Port USB 3 4 Power AC Input 5 Port RJ11 Modem Perlindungan Faks 6 Konektor Output LED fault Menyala Merah LED modus baterai Berkedip Kuning LED modus AC Menya...

Page 11: ...ang lain untuk menghindari interferensi JANGAN menjalankan UPS disaat suhu dan kelembaban berada diluar batas yang telah ditentukan Silahkan periksa spesifikasi untuk mengetahui batasan 20cm 20cm Samb...

Page 12: ...idupkan UPS Masalah Kemungkinan Solusi Tidak ada LED yang menyala pada panel depan Baterai lemah Charge UPS minimal 6 jam Baterai rusak UPS belum dihidupkan Alarm secara terus menerus berbunyi ketika...

Page 13: ...sensing Single GND 230VAC 12 14 230VAC 10 50Hz 1 Battery Mode Simulated Sine Wave Battery Mode Sine Wave AC Mode Typical 2 6ms 12V 10AH 1pc 8 30 mins depending on load 2 4 hours recover to 90 capacity...

Page 14: ...Indonesia Telephone 62 21 3483 1777 Email Support support prolink co id MALAYSIA Office FIDA SYSTEMS M SDN BHD Walk In 29 Jalan USJ 1 31 47600 Subang Jaya Selangor Darul Ehsan Malaysia Telephone 60 3...

Page 15: ......

Page 16: ......

Reviews: