Estimating Cartridge Life
Estimating Cartridge Life
Estimating how long a cartridge will last and the number of days between services
is critical to performing an installation that can be serviced efficiently. This includes
determining the number of Air/Q™ 565s needed for a space. Please refer to Pro-
litec’s ‘Sizing and Consumption Tool’ which is available from Prolitec in an electronic
file. The chart below can be used as a rough guideline for sizing.
Room-Size Table
Output
Level Range
Room Volume
Range in CFT
Room Volume
Range in m
3
1 thru 5
400 – 1,600
11 – 45
6 thru 10
2,000 – 3,400
57 – 96
11 thru 15
3,800 – 5,600
108 – 159
16 thru 20
6,000 – 7,900
170 – 224
21 thru 25
8,550 – 10,700
241 – 303
26 thru 30
11,200 – 13,700
317 – 388
31 thru 35
14,400 – 17,100
408 – 484
36 thru 40
17,900 – 21,000
507 – 595
41 thru 45
21,800 – 25,200
617 – 714
46 thru 50
26,100 – 30,000
730 – 850
These settings are suggested as a starting point. Start on the lower end of the
range and adjust after 15-30 minutes. Fragrance type, room size, number of fresh
air changes per hour, temperature, humidity and user preference will determine the
final setting. Best practice is to use Prolitec’s ‘Sizing and Consumption Tool’ avail-
able from Prolitec as an electronic file.
5