by the overlay.
Digital display shows
relay and particular
zone is overheating.
1. The relay on the switched side is
not opening to regulate temperature.
1. Replace the relay.
92
Beeper not
functioning or
intermittent beeper
sound.
1. Beeper on digital control board
failed.
1. Replace digital controller
board
76
If setpoint is reached
but slightly off in
temperature.
Offset may need to be calibrated and
adjusted.
Call (800) 624-6717 ext. 129 for
instructions.
Heater platen
overheating
If the relay (depending on the year of
the model) on the coil side are
receiving 12vdc indicates the
Controller is functioning properly.
On
the switching side of the relay, is
there 120 vac going to the heater in
question. If there is no voltage on
the to the switching side of the relay
to the heaters, the relay is not
working properly.
Replace relay If the controller's
heat-on LED is not lit indicating
the controller is working
properly.
92
Thickness crank on
top of press
turns endless
Set screws on crank may be loose.
Make sure the shaft is on thin
setting by turning counter
clockwise then tightening the
stacked allen screws (2 set
screws on top of each other) with
allen wrench.
A5
Dough not having
same thickness
across the press
dough.
Adjust upper platen for level press
Underneath the housing there is
4 stacked hex bolts sitting over
the upper platen attached to the
arm. The top bolts are called
locking bolts. The 4 larger hex
bolts below are adjustment bolts.
Break free the 4 locking bolts.
With an open end wrench adjust
the bolts (1/8 turn at a time).
After testing, tighten the locking
bolts making sure not to move
the larger adjustment bolts
11
And
12
Power is on but hear
a leaking of air
The O'rings are warn allowing the air
to pass through the cylinder
The cylinder needs orings, gasket
and new cylinder grease. Request
-----
7