DOUGHPRO
DP1300 Trouble Shooting Guide
If setpoint is reached but slighty off
in temperature.
Offset may need to be calibrated and
adjusted.
Must call (800) 624-6717 ext. 129
for confidential instructions.
___
Heater Platen overheating
If the Relay (depending the year of
the model) on the coil side are
receiving 12vdc indicates the
Controller is functioning properly. On
the switching side of the relay, is
there 120 vac going to the heater in
question . If there is no voltage on
the to the switching side of the relay
to the heaters, the Relay is not
working properly
Replace Relay If the Controller's
heat-on LED is not lit indicating the
controller is working properly.
92
Thickness crank on top of press
turns endless
Set screws on crank maybe loose.
Make sure shaft is all the way on
thin setting by turning counter
clockwise then tighten the stacked
Allen screws (2 set screws on top of
each other) with allen wrench.
A5
Dough not having same thickness
across the press dough.
To adjust upper platen for level press Underneath the housing you will
find 4, stacked hex bolts sitting over
the upper platen attach to the arm.
The top bolts are called locking
bolts. The 4 larger Hex Bolts below
are Adjustment Bolts. Break free the
4 Locking blts. With a open end
wrench adjust the A. bolts (1/8 turn
at a time where needed and test
with dough. After satisfied, tighten
the Locking bolts making sure not to
move the larger Adustment Bolts.
11 & 12
Power is on but hear a leaking of air
under the lower platen / Swing Arm
while Press is idle.
The O'rings are warn allowing the air
to pass through the cylinder
The cylinder needs orings, gasket
and new cylinder grease. Request
instruction sheet and need to order
P/N 110033 for the kit.
___
Press does not close when pressing
the two, green, start buttons
Did not simultaneously press the start
buttons exactly at the same time
Try pressing both buttons eactly at
the same time. This is a anti-tie-
down safety feature.
2
The Lower Platen switch mounted on
the base is not in contact to complete
circuit
Make sure the roller plunger comes
into contact (clicking noise). This is
also a safety feature that both
platens are aligned before
After activation Lower Platen and
when cycle is complete, the Lower
Platen either is very slow coming
down or doesn’t come down at all.
The Mufflers on the Solenoid Valve
are dirty and now allowing alr from
passing though.
Replace both Solenoid Valve
mufflers.
Upon activation, the Lower Platen is
slow to come up and down.
Filter encased in a black housing in
the back of the machine possilby is
dirty.
Replace Filter.