background image

DOUGHPRO

SL1577 Split Lid Grill Trouble Shooting Guide

Symptom

Probable Cause

Action to be Taken

Parts List Ref. #

Power Button on Control face is 
depressed but doesn’t turn on.

Power Cord is not plugged in.

Plug power cord into wall 's 
receptacle and depress power 
button on controller

___

Circuit Breaker is tripped off in the 
site's breaker box

Reset circuit breaker that the Grill is 
plugged into. Depress Power Button 
to turn on.

___

Transformer has taken a electrical 
surge and is damaged

Replace Transformer 

18

Check voltage on the secondary side 
of the Transformer.  If you read 
12VDC then you are receiving voltage 
to the Controller.

Replace Controller.  Controller 
should be on once the power button 
is depressed.

A8

Possibly blown Fuse

Check fuse and repace if necessary

# 98

Digital Controller's LED's are 
scrambled or randomly irratic 

Possibly a componet on the Digital 
Controller is damaged

Replace  the  Digital Controller.  

# A8

Possibly control needs to reset

While unit is on (controller lit up) 
Unplug unit, wait for 1 min. then 
plug machine on and depress power 
button.

___

Digital Controller is constantly 
Beeping

  

No heat on either on left 

right Upper, or Lower  Platen. 
Depress Temp. While depressing 
Temp., depress either up or down 
arrow to locate error 
message,"PROB" (zone 1, Lower 
Platen, zone 2 Left Upper Platen, 
zone 3, right Upper Platen.) 

.  

If 

occurred when depressing the up 
arrow indicates either the left or 
right Upper Platen has the open 
sensor or probe.  same goes for the 
down arrow indicating Lower Platen.

Sensor in one of two zones lost it's 
continuity. Depress Temp. While 
depressing Temp., depress either up 
or down arrow to locate error 
message,"PROB" (zone 1, Lower 
Platen, zone 2 Left Upper Platen, 
zone 3, right Upper Platen.) .  If 
occurred when depressing the up 
arrow indicates either the left or right 
Upper Platen has the open sensor or 
probe.  same goes for the down 
arrow indicating Lower Platen

Disconnect prob and check for 
continuity (by using Ohm Meter) and 
replace.  Do not cut and splice new 
sensor. Install new 2000 ohm RTD 
sensor to under side of Heat Platen 
and reconnect to Controller.  Upper 
left and right sensor for replacement 
on upper platens, Lower Platen 
sensor for replacement for Lower 
Platen.

# 22                                   
# 46      

Digital Controller is beeper chirping 
and is over heating.  

The Mechanical Relay on the 
switched side is not opening to 
regulate temperture.  Same as above, 
hold Temp button then depress 
either the down or up arrow (zone 1, 
Lower Platen, zone 2 Left Upper 
Platen, zone 3, right Upper Platen.) 
which ever zone is the problem, you 
will see RLY indicating the damage (in 
closed position) .

Replace the Mechanical Relay.

#15

One of the three Heater Platens not 
close to set point. 

The offset function in the Controller's 
setting needs to be adjusted to 
achieve proper shade of toast. 

Call Doughpro (800) 624-6717 for 
instructions.  This information must 
not to be given to operators of the 
SL1577.  They may get confused and 
cause further temperature 
discrepancies.

____

Beeper not functioning 

Beeper has failing.

Replace Controller board

# A8

Summary of Contents for TACO BELL PROGRILL SL1577TB

Page 1: ...formerly DOUGHPRO New Name Same Quality Superior Service proluxe com Operations Manual Model SL1577TB Split Lid Grill revC 101416 ...

Page 2: ... the power switch which will illuminate when turned on The display flashes and shows left preset timer during warm up Pre heat temperature time will be 40 50 minutes When the set point is reached the display stops flashing and beeps 3 times Step 4 Operation Simply place product on either side of the grill close lid and press the desired pre set time cycle 10 or 20 seconds After the time cycle is f...

Page 3: ...t is turned on All preset LED s are turned off and the temperature set point is changed to the clean set point of 275 F This also initiates the cool down to clean set point condition as well the display starts flashing until the clean set point is reached To stop the clean cycle simply press the CLEAN button once to deactivate the clean cycle The CLEAN LED is turned off the preset LED s are restor...

Page 4: ... temperature of the UPPER PLATENS Press the TEMPERATURE button and the ARROW UP button at the same time 2 To find the temperature of the LOWER PLATENS Press the TEMPERATURE button and the ARROW DOWN button at the same time 275 is the factory default temp for the CLEAN cycle To change the CLEAN cycle temp simultaneously hold down the TEMP and CLEAN buttons for 15 seconds The current temp setting wi...

Page 5: ...timer button and continue to hold both for 5 seconds The digital displays will now read their preset times as shown here Each side is capable of having up to 4 different settings making a total of 8 set times Now using the ARROW buttons you can set your desired time Once you have set the desired time simply press the TEMP button the unit will display the new set time IMPORTANT NOTE When adjusting ...

Page 6: ...t Upper Platen has the open sensor or probe same goes for the down arrow indicating Lower Platen Sensor in one of two zones lost it s continuity Depress Temp While depressing Temp depress either up or down arrow to locate error message PROB zone 1 Lower Platen zone 2 Left Upper Platen zone 3 right Upper Platen If occurred when depressing the up arrow indicates either the left or right Upper Platen...

Page 7: ...With use of a Ohm Meter a condinuity check must check at the cold pins of the heater where the heater wire is brazed at the cold pin This will eliminate any other failue before the the heater element validating the loss off condinuity at the source Heater Element If so either the Upper left zone 2 right zone 3 or Lower 15 Either Upper Heater not coming down parallel to the Lower Heater Platen Para...

Page 8: ...EXPSL1577TBA RC 101216 SHEET 1 OF 2 79 2X 74 2X 73 2X 46 2X 55 2X 54 2X 40 70 4X 1 28 4X 72 42 2X 4X 2X 63 52 4X 71 75 4X 3 64 77 52 12X 45 76 78 2 68 A1 A2 ...

Page 9: ... 2X 56 2X 33 16 84 6X 87 80 70 34 35 71 82 86 83 22 2X 21 2X 20 2X 5 2X 2X 14 92 53 6X 31 6X 93 6X 3X 95 69 48 84 30 10 8X 66 65 3X 13 3X 9 6X 4 35 39 34 2X 48 17 2X 2X 37 19 18 2X 44 29 89 3X 90 17 3X 3X 91 36 4X 41 49 32 2X 15 12X 24 2X 23 2X 26 29 2X 58 61 59 61 59 25 27 60 61 60 59 4X 10 2X 47 38 6X 31 6X 53 62 2X 50 2X 11 4X 57 2X 67 81 A7 A4 A8 A3 ...

Page 10: ...29 BUSHING TEFLON 3 4 LONG 110113441 110113441 6 30 GREASE TRAY 110115505 110115505 1 31 NUT HEX 6 32 NH632 NH632 12 32 TOP LINK 110115508 110115508 2 33 WIRE HARNESS 1101102050 1101102050 1 34 UPPER LEVELING BRACKET 110115510 110115510 2 35 UPPERLEVELING SHIM 110115557 110115557 2 36 PIN PIVOT FRONT 11017088865 11017088865 2 37 BOLT HEX 5 16 18 X 1 STAINLESS STEEL BH516181S BH516181S 4 38 BACK CO...

Page 11: ...5513 1 82 SCREW SET 3 8 16 x 1 2 SST381612 SST381612 2 83 RTD SENSOR 1108881101 1108881101 2 84 SCREW PAN HEAD PHILLIPS 10 24X3 8 STAINLESS STEEL SP102438S SP102438S 12 85 SHROUD LEFT ASSEMBLY 11016546454 11016546454 1 86 SHROUD RIGHT ASSEMBLY 11016546455 11016546455 1 87 INSULATION UPPER PLATEN 110888251 110888251 2 88 CLEVIS ASSEMBLY LEFT HAND 110115503 110115503 1 89 CLEVIS ASSEMBLY RIGHT HAND ...

Page 12: ......

Page 13: ...mpany s products the following instructions must be adhered to First contact our customer service department for approval and a return authorization number Please have the serial number of your item available at that time All merchandise must be shipped freight prepaid by customer or service agency Subject to the inspection of the product by the company a restocking charge of 20 of the Net purchas...

Reviews: