background image

PROMAG 

DF7XX 

REV.C 

 

 

Mifare

®

 User-Data Format 

DF7XX reader will send out the data following the format as below, the user data length defined by the 

Data-Info. At Wiegand output format, the data output length is fixed (defined by Number Of Bits), so the user 

data would be cut if longer than Number of Bits, or the user data would b

e appended with zero “0” if shorter 

than Number of Bits. 

 

Byte 0 

Byte 15 

 

Application 

Sector # 

Block 0 

Data-Info 

 

Block 1 

USER DATA (Max 128 Bytes) 

Block 2 

Block 3   

 

Data-Info 

bit7      bit6 

bit5                                                     bit0 

Data Type (11b) 

Data Length 

Data Type is fixed with 11b 

which meets “any other data” type of “Card Holder information” as MAD standard. 

And data length is including the data with ending zero 

“0”, so the number of data byte sent by DF7XX reader is 

equal to data length with one less for RS232 output. 

Example: Data Length is 16, DF7XX reader only sends out 15 bytes for RS232 output. 

 

Summary of Contents for Mifare DESFire

Page 1: ...Mifare DESFire Reader User s Manual For DF7XX Series REV C November 30 2011...

Page 2: ...Buzzer Settings 11 5 Wiegand Setting 13 6 ABA TK2 Settings 14 7 RS232 Output Setting 15 8 Configured Card 17 9 Test Reader After Update 18 ANNEX A Hardware Specification 19 ANNEX B Wiegand Interface...

Page 3: ...so be set with a Reader ID number for multi unit communication Features 1 Support MAD1 MAD2 MAD3 standard and support customer MAD AID setting 2 Support Non MAD format with user defined sector number...

Page 4: ...Auto Mode Get Application Sector Request Anti collision Is MAD Card AID Match Using DF700 Non MAD Sector Un know Read Sector Data Output Data No Tag Card On Reader No Yes No The DESFire Reader will se...

Page 5: ...h zero 0 if shorter than Number of Bits Byte 0 Byte 15 Application Sector Block 0 Data Info Block 1 USER DATA Max 128 Bytes Block 2 Block 3 Data Info bit7 bit6 bit5 bit0 Data Type 11b Data Length Data...

Page 6: ...UZEER IN External LED BUZZER Control To configure the DF7XX Reader you need connect the reader to the MF700KIT first as below DF700 DF750 CP GND D1 D0 RX TX VCC MF700KIT MF700 9VDC WAS T0029 BLACK WHI...

Page 7: ...e application open system AID 000000h FFFFFFh Or it is also possible for the user to define the AID himself for the application in user defined closed system without registering into MAD group Accordi...

Page 8: ...ata on the card with the same KEY 2 Mifare Settings Click Card Type Mifare Only or Both and this tab will be visibled MAD AID Default 4703 MAD Application Identifier number is authorized and assigned...

Page 9: ...t 4 Encrypt 5 to protected your card data Remark Encrypt mode must to work together with the same encrypt mode of Mifare Card Issuer software Used Card Not issued by Mifare Card Issuer You have to ind...

Page 10: ...ata Only a Card Data Only Read card sector data only If any error ex mifare key error reader will show Card Invalid status b Card Data or CSN Card Serial Number Read card sector data If any error ex m...

Page 11: ...iptions 0 30h All LED Off Buzzer Off 1 31h Green LED ON 2 32h Green LED OFF 3 33h Red LED ON 4 34h Red LED OFF 5 35h Buzzer Beep once 6 36h Buzzer Beep 3 Times 7 37h Green LED ON with Beep once 8 38h...

Page 12: ...nd beeps to indicate the end user when brown wire Inactive or card was failed by DF7XX Reader Brown wire Active Show LED color and beeps to indicate the end user that brown wire Active signal from Hos...

Page 13: ...e only combines with CSN output Default Disable Number of Bits is to set the Wiegand output type you want to meet your Host or Terminal It can be 1 to 128 Default 26 Bit Sequence is to set the Wiegand...

Page 14: ...ata Default Disable Output Data Order Set the TK2 output data sequence order Default MSB First Source Data Order Set the TK2 source data sequence order Default MSB First Data Conversion Select card da...

Page 15: ...600bps Data Sequence can be set LSB first and MSB first Default Package is to set the output data packet to include Header Reader ID Data Length CR LF and Trailer Header 00h FFh Trailer 00h FFh Defaul...

Page 16: ...all configuration items are write only so any users can not read the configuration items from DF7XX reader to get the App Key that is very important to protect your App Key and all configuration items...

Page 17: ...PROMAG DF7XX REV C 17 8 Configured Card Configured Card Enabled can allow your reader change configuration by Mifare Card Key is the Mifare Key A for allowed configured card...

Page 18: ...stored 1 After set configurations in the Reader Utility software you can click Update Reader to update the currently configurations to the reader 2 Or click Test to update configurations and verify ou...

Page 19: ...quency 13 56MHz RF Distance2 50mm Using the MFA01 Mifare card of GIGA TMS INC DC Power 7 5VDC 24VDC Min 250mA 7 5V 150mA 12V Interface Wiegand 26 128 bits Standard Reverse RS232 2400bps 57600bps ABA T...

Page 20: ...s for the DF7XX Reader Data 1 Signal Data 0 Signal Tpw Tpi Tpw Tpi Pulse Times Symbol Description Typical Time Tpw Pulse Width Time 100us 3 Tpi Pulse Interval Time 1 9ms 3 Wiegand Packet Without Reade...

Page 21: ...d by the user with the leading edge negative of the Strobe CARD PRESENT Card Present will go low after flux reversals from the Reader Card Present will return high after the last flux reversal Connect...

Page 22: ...PROMAG DF7XX REV C 22 ANNEX D RS232 Interface Connect the RS232 wires example as below HOST Terminal Optional External LED Buzzer Control Brown Red GND Black DF700 7 5 24VDC GND GND TXD Yellow...

Page 23: ...rol the LED Buzzer of DF7XX reader Examples as below Active High 1 Show External Invalid Status Data Output Alarm Control Brown 2 Show Card Valid Status Data Output Alarm Control Brown Note 1 Send one...

Page 24: ...DF700 00 DF700 00 DF700 DESFire Configurable Reader MF700KIT 10 MF700KIT WAS T0029 DISK5238 Power Adaptor Reader Kit MF7XX Configure Cable Card Issue and Utility Software DC Power Adaptor 9VDC for MF...

Page 25: ...eps as below First of all you need to connect the reader or programmer to PC and make sure they were power on Step 1 Input your account UserName and Password Note Contact us to get your account when n...

Page 26: ...or programmer s firmware out of date then WebISP will prompt you to update the firmware Click Update to begin Updating the firmware Step 4 Wait for the updating to finish And repeat step 2 to update...

Page 27: ...rd when the Configured Card Enabled is enabled Step 1 Connect the PCR310 to PC for issuing card Click Auto Scan Choose DF700 DF750 Series Choose DF700 00 DF750 00 Click OK Remark DO NOT connect the re...

Page 28: ...ROMAG DF7XX REV C 28 Step 3 Type in correct Configured Key as same as reader configured before Put an empty Mifare Card Click Create Finish Take this card to approach the reader for configured setting...

Page 29: ...egand 4 bits Wiegand 6 bits Wiegand 8 bits ASCII Hex Code Buffering Decimal 1 0001 000010 11100001 31 00 00 0 65535 2 0010 000100 11010010 32 00 00 3 0011 000111 11000011 33 00 00 4 0100 101001 101101...

Page 30: ...2009 Issue DF7XX Reader Rev B October 29 2009 Fix power supply 7 5V 24VDC Rev C November 30 2011 Kylie Update Mifare Reader Utility Pics Modify Reader ID to 0 63 Add Source Data Order P 14 Modify Sequ...

Page 31: ...PROMAG DF7XX REV C 31 PROMAG GIGA TMS INC http www gigatms com tw mailto promag gigatms com tw TEL 886 2 26954214 FAX 886 2 26954213 Office 8F No 31 Lane 169 Kang Ning St Hsi Chih Taipei Taiwan...

Reviews: