5.1

 

 

Introduction

 

 

The transmodulator is controlled and configured via Ethernet using a standard 
browser. The webserver application provides access to the setting parameters of 

the modulator. To use it you need just a standard browser and an internet 
connection. In this way remote control can be done from any PC computer using 
the integrated webserver which does not require installation of any additional 
software. 

The webserver application allows the user to work remotely on the instrument in 
a more comfortable way, whether to check status of signal output, to set 
parameters, to change selected services, for general maintenance, etc. User can 
also dynamically change the programme grid without need to retune every TV on 
the system. 

 

5.2

 

 

First Connection

 

 

The default IP of this device is 192.168.29.30. 

  In first place, check the IP address of the PC. It must be in the same IP 

range of the device. This means, an IP like 192.168.29.xxx (xxx can be 0 to 
255 except 30 to avoid conflict with module IP address). Add a new IP or 
change the current one to meet this requirement. 

  Check connections. The Ethernet cable must be connected to the control 

input (see figure 3 – (number 7)). It is recommended to try a ping on the 
command-line interface to confirm they are on the same network range and 
communication between them is possible. 

  Now use a web browser to run the webserver application from the PC. Write 

the IP address (by default 192.168.29.30) on the URL bar and press ENTER. 

  If connection is successful, the browser will display a login screen (see 

description chapter). Enter the Username and Password (by default both are 
“Admin”) then click on ‘Login’ to enter the webserver application. 

NOTE

:  After communication is established, the user can set a new IP address on 

the module to suit the range of its own Ethernet network or PC. 

NOTE

:  Write down the new IP address if you change the default IP address, as it 

is required each time you want to communicate. 

 

Summary of Contents for CompactMax-5

Page 1: ...CompactMax 5 DVB S S2 TO IPTV TRANSMODULATOR 0 MI2199...

Page 2: ...he equipment means SEE USER S MANUAL In this manual may also appear as a Caution or Warning symbol WARNING AND CAUTION statements may appear in this manual to avoid injury hazard or damage to this pro...

Page 3: ...the specified environmental conditions The user is not allowed to perform changes inside the equipment Any change on the equipment must be done exclusively by specialized staff Do not obstruct the ve...

Page 4: ...with safety Descriptive Examples of Over Voltage Categories Cat I Low voltage installations isolated from the mains Cat II Portable domestic installations Cat III Fixed domestic installations Cat IV...

Page 5: ...ON 5 1 7 Introduction 7 5 2 7 First Connection 7 5 3 9 Screen description 9 5 4 9 Status Area 9 5 5 10 Edit options 10 5 6 11 Setting parameters 11 5 6 1 12 Versions Store 12 5 6 2 13 Control 13 5 6 3...

Page 6: ...through this process there are 10 independent streams IPTV SPTS or MPTS that can be inserted into a television distribution network The CompactMax is managed through a webserver via remote control LA...

Page 7: ...It can be used in hotels convention centres hospitals ships emblematic buildings mansions etc Figure 1 2 June 2021...

Page 8: ...June 2021 3 2 PACKAGE CONTENT Main Unit Quick guide Power line...

Page 9: ...3 DESCRIPTION Front view Figure 2 1 Power On indicator 2 Error indicator 3 Common Interface input CI 1 for decoder card 4 Common Interface input CI 2 for decoder card 5 IP address reset 4 June 2021...

Page 10: ...ignal DVB S S2 free channels 9 Input 3 for satellite signal DVB S S2 free channels 10 Input 2 for satellite signal DVB S S2 scrambled channels connected to CI 2 11 Input 1 for satellite signal DVB S S...

Page 11: ...6 June 2021 4 ASSEMBLY INSTRUCTIONS 4 1 Rack mounting Figure 4 4 2 Wall Mounting Figure 5...

Page 12: ...must be in the same IP range of the device This means an IP like 192 168 29 xxx xxx can be 0 to 255 except 30 to avoid conflict with module IP address Add a new IP or change the current one to meet t...

Page 13: ...The error LED will flash Press and hold the button until the LED stops blinking At this time the IP adress has changed to the default IP 192 168 29 30 This change is temporary and if you turn the equ...

Page 14: ...cific set of parameters Setting Parameters area Set of parameters according to the tab selected Edit options Options to edit parameters Status area Transmodulator current state In the following sectio...

Page 15: ...button shows which one is working and its status green ok red error IPTV It shows the status for each independent IPTV stream The radio button shows which one is working and its status green ok red d...

Page 16: ...ettings Logs Information about transmodulator operation Receivers Satellite receivers settings nditional Access Module CAM settings CAM Co Input Services Information about services captured from satel...

Page 17: ...uipment model name and serial number among others Store fields It applies and saves all changes made in the webserver on the transmodulator Reboot It reboots the transmodulator Reset to factory defaul...

Page 18: ...er Mask Network parameter t 255 255 255 0 by defaul Gateway Network parameter by default 192 168 29 1 Change password It allows the user to change the password to access the webserver application user...

Page 19: ...dow gives information about the transmodulator operation Each event happening in the modulator is captured and shown on this window Each event has a description a tag and an identification number Figu...

Page 20: ...y MHz Oscillator frequency of the antenna in MHz If you have a Universal LNB generally are 9750 MHz for LOW band and 10600 MHz for HIGH band Downlink frequency MH frequency of the satellite z Tuning P...

Page 21: ...can browse through the CAM module menu Figure 12 Each time an option is selected from the CAM module menu user should wait until the system accesses the next menu or option Each CAM module has its ow...

Page 22: ...about the services captured Available information is Transport stream identifier It is a number that identifies the transport stream Original network identifier It is a number that identifies the net...

Page 23: ...specific transport stream Original network identifier It is a number that identifies the network nal comes from where the sig Private data specifier Data that the receiver uses to properly identify th...

Page 24: ...d down MAC address It shows the physical address of the device Interface IP Enter the IP Address for the interface Mask Subnet mask of the equipment by default 255 255 255 0 Total out bit rate kbps It...

Page 25: ...ven value TS packets per IP TS packets per IP packet by default 7 FEC enabled Check to enable FEC Forward Error Correction L Number of columns for FEC matrix D Number of rows for FEC matrix FEC arrang...

Page 26: ...TP with FEC SMPTE 2022 1 2 compliant CONDITIONAL ACCES Two Common Interface DVB CI compliant slots TS PROCESSING Selection of arbitrary number of services from the received TS bit rate of the input se...

Page 27: ...ion of the problem or the service r You should retain kaging materials on a permanent basis if ne equipment to th cal Assi Cleaning Recommendations CA To clean re the instrument is disconnected UTION...

Page 28: ...June 2021 23...

Reviews: