USER'S MANUAL FP-2b
Janvier 2001
Page 5
AC Current
Range
Resolution
Accuracy
20 mA
10
µ
A
±
(1% r 3 dig.)
200 mA
100
µ
A
±
(1.8% r 3 dig.)
10 A
1 mA
±
(3% r 7 dig.)
Overload protection:
By fuse
(10 A range without protection)
Frequency range:
40 Hz up to 400 Hz
Maximum input current:
10 A in continuous mode, 20 A, 15 s maximum
Response:
Average, calibrated in rms of sine wave
Resistance
Range
Resolution
Accuracy
200
Ω
0.1
Ω
±
(0.8% r 3 dig.)
2 k
Ω
1
Ω
20 k
Ω
10
Ω
200 k
Ω
100
Ω
2 M
Ω
1 k
Ω
±
(0.8% r 1 dig.)
20 M
Ω
10 k
Ω
±
(1% r 2 dig.)
200 M
Ω
100 k
Ω
±
(5% (reading –10 dig.) + 10 dig.)*
*
On 200 M
Ω
range, if inputs are short circuited, display will read 10 digits
approximately (minimum resolution units). This reading should be
subtracted from the readout.
Overload protection:
250 V DC/AC rms
Summary of Contents for FP-2b
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ...USER S MANUAL FP 2b Page 2 Janvier 2001...
Page 14: ...USER S MANUAL FP 2b Page 8 Janvier 2001...
Page 21: ...0 IG2564...