INSTRUCTION MANUEL. PROMAX-8+
Page 36
May 2001
PROMAX-8+
LOGGER NUMBER
10
DATE: 09:59
10-10-1999
CHANNEL PLAN:
CCIR
AUDIO:
5.50 MHz (FM)
UNITS:
dBuV
THRESHOLD:
OFF
NOISE FREQ.:
BW/2
CHAN
FREQ
V
V/A
C/N
C23
487.25
76
14
52
C25
503.25
53
9
33
C27
519.25
81
16
55
C29
535.25
59
13
39
C31
551.25
78
16
44
C34
575.25
67
11
45
C37
599.25
54
7
34
C38
607.25
57
14
>37
C39
615.25
62
18
>42
C41
631.25
71
14
43
C43
647.25D
43
13
Figure 39.- Example of print.
4.2.6.1
Data LOGGER configuration.
From the LOGGER mode, when
pressing the CONFIG key [14] we will
accede to the configuration menu. This
menu permits to modify the
THRESHOLD and MEASURES parameters. To
accede to them turn the rotary selector and once
the parameter we want to change is appears
shadowed, press it; then turning it its value will be
modified. Finally press it again to validate the new
value.
a) THRESHOLD: It activates / deactivates the measurement threshold.
This parameter allows to carry out the logger function in an agile way, by
activating only those measures we consider significative.
In the OFF mode (deactivated) all measurements are taken (with a level
higher than 20 dBµV). On the other hand, when a level is defined, only
those channels with a level higher than the THRESHOLD value will be
measured.
Figure 40.- Logger configuration
menu.