Flow rate
The flow rate is transmitted by 4 binary bytes (32-bit integer coded). The following
possibilities of the VIF value exist:
Transferred unit
VIF
1 m³/h
3Eh
100 L/h
3Dh
10 L/h
3Ch
1 L/h
3Bh
0,1 L/h
3Ah
0,01 L/h
39h
0,001 L/h
38h
1 L/min
44h
0,01 L/min
43h
0,001 L/min
41h
1 L/s
4Eh
0,1 L/s
4Dh
0,01 L/s
4Ch
0,001 L/s
4Bh
software version
format 8 bit integer
alarms (8 bit integer)
Bit 0
Add volume overflow (inappropriate increase)
Bit 1
Frame error
Bit 2
empty pipe
Bit 3
input/ output overflow
Bit 4
reserved
Bit 5
reserved
Bit 6
reserved
Bit 7
reserved
Total length of the frame: 70 bytes