Maintenance manual Universal-1000
P R O M E T A L
40
Lubrication plan for vibrators
Mould vibrators
During an 8 hour continuous operation lubrication should be done according to the following
index:
Type VZ-280 400h operating hours
with 6 strokes of a grease gun (0.8g grease each)
After lubricating for the 10th time, disassemble the vibrator, clean and grease the antifriction
bearing.
It is done by:
1.
Dissasemble vibrator
2.
Clean all parts
3.
Examine parts for damage and replace if necessary
4.
Fill antifriction bearings with grease
Lubricants can be obtained through PROMETAL
Multi-purpose greases are not appropriate and
should not
be used. In order to avoid any
confusion with unfit greases, use above mentioned grease also for all other greasing points of
the machine.
Tamper head vibrators
All bearings are correctly lubricated on mounting the vibrator.
Never mix greases even if they have similar features. Excessive quantity of grease causes
increased heating of the bearings and consequent anomalous current absorption.
Lubricants can be obtained through PROMETAL
Summary of Contents for UNIVERSAL 1000
Page 19: ...Maintenance manual Universal 1000 P R O M E T A L 19 ...
Page 25: ...Maintenance manual Universal 1000 P R O M E T A L 25 Hydraulic system ...
Page 26: ...Maintenance manual Universal 1000 P R O M E T A L 26 ...
Page 52: ...Maintenance manual Universal 1000 P R O M E T A L 52 Now lower down tamper head and mould ...
Page 53: ...Maintenance manual Universal 1000 P R O M E T A L 53 Pull out cart with mould on itself ...
Page 58: ...Maintenance manual Universal 1000 P R O M E T A L 58 After adjustment is done ...
Page 65: ...Maintenance manual Universal 1000 P R O M E T A L 65 Vibrator table maintenance ...