Maintenance manual Universal-1000
P R O M E T A L
47
- check that the tamper head securing bolts are putted in securing position
- check the rubber buffers on mould clamping
- check the easy movement of mould clamping
For a mould change it is important to observe that filler box guide on filler box under plate is
in line with filler box guide on mould.
Distance of a mould to filler box under plate must be approx. 1mm.
The area around mould guide should be cleaned whenever possible, to reduce the possibility
of wear on the guiding elements. Check this area daily (based on 1-shift operation), and clean
if needed!
Never
perform any setup, repair or maintenance work with mould guide lifted up!
Before You start any setup, repair or maintenance work
first insert safety bolt!
For mould change please follow next procedure:
Mould and tamper head dismantling
-
check that filler box is in start position
-
move up mould for about 25 cm under floor
Turn in position OFF main switch on electric board before continue
with next mould change steps!
-remove protective meshes from both sides of machine that you can reach screws that tight
mould to mould clamping part
-unscrew mould from mould clamping part
-low down tamper head into mould that distance holders are laying on moulds up surface
SAFETY NOTE!
Turn in position OFF main switch on electric board before continue with next mould
change steps!
-unscrew all 12 screws that hold tamper head tighten to tamper head bridge
-unscrew holders of electric cables that supply tamper head vibrators and pull out cables
-Put under the mould holders (wooden or other) 5-10 cm of height
SAFETY NOTE!
Summary of Contents for UNIVERSAL 1000
Page 19: ...Maintenance manual Universal 1000 P R O M E T A L 19 ...
Page 25: ...Maintenance manual Universal 1000 P R O M E T A L 25 Hydraulic system ...
Page 26: ...Maintenance manual Universal 1000 P R O M E T A L 26 ...
Page 52: ...Maintenance manual Universal 1000 P R O M E T A L 52 Now lower down tamper head and mould ...
Page 53: ...Maintenance manual Universal 1000 P R O M E T A L 53 Pull out cart with mould on itself ...
Page 58: ...Maintenance manual Universal 1000 P R O M E T A L 58 After adjustment is done ...
Page 65: ...Maintenance manual Universal 1000 P R O M E T A L 65 Vibrator table maintenance ...