To allow exact adjustment of the weights, the
vibrators are equipped with a patented
system that prevents the adjustable weight to
turn in the wrong direction .
Unscrew the mobile weight screw fastener or
nut. The adjustable weights positioned at the
two ends of the shaft must be positioned in a
way to read the same value on the reference
percentage scale. The weights positioned at the
two sides of the vibrator can only be adjusted on
two different values for particular machines and
for special uses.
- Once the eccentric weight has been taken to the desired value tighten the screw fastener or
nut using the dynamometric wrench (picture bellow) and repeat the same operation on the
opposite weight.