Type
Pump capacity
at maximum back pressure
Pump capacity
at medium back pressure
Con‐
nector
size
outer
Æ
x inner
Æ
Suction
lift*
Priming
lift**
Max.
priming
pres‐
sure on
the suc‐
tion
side
2
bar
l/h
ml/
stroke
bar
l/h
ml/
stroke
mm
m water
column
m water
column
bar
0713
7
10.5
0.97
3.5
12.3
1.14
8x5
3.0
1.8
3.5
0420
4
15.6
1.44
2.0
17.4
1.61
12x9
3.0
1.8
2
2
The pressure on the discharge side needs to be at least 1.5 bar higher than the pressure on the suction
side. We therefore recommend installing a back pressure valve on the discharge side to adjust the
increased pressure. This will avoid excess pumping.
*
- Suction lift with a filled suction line and filled liquid end. With
self-degassing dosing head with air in the suction line.
** - Priming lifts with clean and moist valves. Priming lift at 100%
stroke length and free drain or opened vent valve.
*** - The given performance data constitutes guaranteed min‐
imum values, calculated using water as the medium at room
temperature. The bypass connection with a self-degassing
dosing head SEK is 6x4 mm.
*** - The stated performance data represents minimum values
calculated using water as the medium at room temperature.
1
- The connector width is 6 mm with SST material versions.
Metering pumps with dosing heads for higher-viscosity (HV) media
have a 10-20% lower dosing rate and are not self-priming. Con‐
nector G 3/4-DN 10 with hose sleeve d16-DN10.
16.1.1 Performance data with vPTFE diaphragm
Tab. 8: At 180 strokes/minute and 100% stroke length
Type
Pump capacity
at maximum back pressure
Connector
size
outer
Æ
x
inner
Æ
Suction lift* Priming
lift**
Max. pri‐
ming pres‐
sure on the
suction
side
1
Beta b
bar
l/h
ml/stroke
mm
m water
column
m water
column
bar
1602
10
2.2
0.21
6x4
5.0
2.0
5
1604
10
3.7
0.34
6x4
5.0
2.0
5
0708
7
7.1
0.66
8x5
4.0
2.0
3.5
1008
10
6.8
0.63
8x5
3.0
2.0
5
0413
4
11.3
1.05
8x5
3.0
2.0
2
Technical data
57