5.
Protect yourself against the feed chemical if the liquid end
has not been flushed in accordance with the above pro‐
cesses - protective clothing, safety goggles, ... .
After dismantling, immediately place parts that have been
wetted by the medium in a trough with a suitable medium for
flushing – be sure to rinse hazardous media thoroughly.
6.
Unscrew the hydraulic connectors on the discharge and suc‐
tion side.
1
2
3
4
5
6
7
8
9
P_MA_0038_SW
Fig. 18: Cross-section through liquid end
1 Dosing head
2 Diaphragm
3 Reinforce plate
4 Screw
5 Leakage hole
6 Slide rod
7 Threaded connection
8 Turret
9 Backplate
Repairs