CAUTION!
Unauthorised operating parameters
Possible consequence: Material damage
Ensure that:
– The installation place is dry and frost-free
– There is guaranteed protection for the UV
system from chemicals, dyes and vapours
– The ambient temperature and the radiation
temperature in the direct vicinity of the system
do not exceed 40°C
– The maximum permissible operating pressure
is not exceeded and
– There are no solid particles and no turbidity in
the water to be treated
– If necessary, fit a suitable filter prior to the UV
system.
3.4 Safety equipment
ATTENTION: Hazardous ultraviolet radiation
UV-C
UV-C radiation is harmful to the eyes and skin! The UV lamps
may only be operated when installed. The UV system should be
installed in accordance with all pertinent regulations prior to com‐
missioning the UV lamps.
ATTENTION: Hazard
Disconnect the system from the mains power supply or switch
off the master switch prior to commencing maintenance work.
Depressurise the reactor prior to commencing maintenance work.
Disconnect the system from the mains power supply or switch
off the master switch prior to opening.
3.5 Information in the Event of an Emergency
In the event of an emergency, switch the red-yellow main switch on
the side of the control cabinet to OFF or disconnect from the mains
power supply.
Labels on reactor
Labels on control cabinet
Safety chapter
14