External control of lamp output / UV intensity is not possible in
power stage 2. In the
‘External UV lamp control’ control mode, the
UV system controls to the set nominal dose of power stage 2.
A1438
Menu
Control and setpoint of UV
Automatic
Nominal dose 1:
HOME
Manual mode
600 J/m
2
activated
500 W/m
2
Setpoint:
(m
3
/h)
Aut-Lev1
Aut-Lev2
Fig. 31: [Control and setpoint of UV] in control mode: automatic
lamp control/power stage 1.
A2909
Menu
Control and setpoint of UV
Automatic
Nominal dose 2:
HOME
Manual mode
400 J/m
2
activated
335 W/m
2
Setpoint:
(m
3
/h)
Aut-Lev1
Aut-Lev2
Fig. 32: [Control and setpoint of UV] in control mode: automatic
lamp control/power stage 2.
1.
Use the
[TAB] key to select the value to be adjusted.
2.
Now press
[ENTER].
ð
The message
[Function keys are deactivated] now
appears; you can now enter the desired value using keys
0 ... 9.
3.
Enter the desired value.
4.
Confirm the value with
[ENTER].
5.
Now press
[F5] [Menu].
ð
The entered value is saved and the display again shows
selection of the second operating and display level.
Control
41