You can call the function
[Calibrate touch]
via the button
[Activate]
. This is
for renewed calibration of sensors if the touch function is insufficiently
accurate.
1.
Press
[Activate]
2.
Touch the displayed cross five times with the finger
3.
Touch the touch panel once more so that the calibration value is
accepted
10.4 Concentration
If the PROFIBUS
®
or PROFINET
®
are included in the scope
of supply, the [Concentration] and the [Intern] / [Extern] keys
appear on the display. In [Intern] mode, the setpoints for the
concentration (Powder and Liquid) are specified by the con‐
trol panel. The process management system can only read
data. In [Extern] mode, the setpoints for the concentration
are specified by the process management system. Addition‐
ally in [Extern] mode, the Ultromat can be switched to Pause
and a fault acknowledged using the profibus. Further infor‐
mation is available in the supplementary PROFIBUS
®
or
PROFINET
®
instructions. If the PROFIBUS
®
or PROFINET
®
are not connected, select the [Intern] setting.
Mode
Menu
Archive
Reset
Concentration
Unit Stop
Powder concentration:
Liquid active ingredient:
A0823
Liquid concentration:
Internal
External
Fig. 36: Concentration Powder / Liquid
Parameters
Factory setting
Setting range
Powder concentration
0.5 %
0.05 - 2.00 %
Liquid concentration
0.5 %
0.05 - 2.00 %
Liquid active ingredient
100 %
10 - 100 %
PROFIBUS
®
/PROFINET
®
(Intern / Extern)
Intern
Intern or Extern
Calibrate touch:
Operating Menu [F2]