Chapter 6: Maintenance
209
1.
From the Main Menu, highlight
Additional Info and Management
, and press
Enter.
2.
Highlight
Shutdown or Restart
and press Enter.
3.
Press the spacebar to display
Restart
then press Enter.
A warning message appears.
4.
Press Y to continue.
The screen will go blank.
5.
Wait for two to three minutes.
6.
Re-establish your Telnet connection to the VTrak CLU.
If you cannot re-establish a connection, wait 30 seconds, then try again.
Restarting Subsystem over a Serial Connection
To restart the VTrak subsystem on a serial connection:
1.
From the Main Menu, highlight
Additional Info and Management
, and press
Enter.
2.
Highlight
Shutdown or Restart
and press Enter.
3.
Press the spacebar to display
Restart
then press Enter.
A warning message appears.
4.
Press Y to continue.
The screen will display shutdown and startup functions.
5.
When the
Login:
prompt appears, log into the CLU again.
Warning
Do not restart the VTrak during a firmware upgrade procedure.
Wait until the upgrade is one and you are prompted to restart.
Summary of Contents for E310f
Page 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Page 14: ...VTrak E Class Product Manual xiv ...
Page 22: ...VTrak E Class Product Manual 8 ...
Page 58: ...VTrak E Class Product Manual 44 ...
Page 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Page 218: ...VTrak E Class Product Manual 204 ...
Page 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Page 304: ...VTrak E Class Product Manual 290 ...
Page 316: ...VTrak E Class Product Manual 302 ...