VTrak E-Class Product Manual
228
RAID 50 – Striping of Distributed Parity
RAID 50 combines both RAID 5 and RAID 0 features. Data is striped across
disks as in RAID 0, and it uses distributed parity as in RAID 5. RAID 50 provides
data reliability, good overall performance and supports larger volume sizes.
Figure 5. RAID 50 Striping of Distributed Parity disk arrays
RAID 50 also provides high reliability because data is still available even if
multiple disk drives fail (one in each axle). The greater the number of axles, the
greater the number of disk drives that can fail without the RAID 50 array going
offline.
RAID 50 arrays consist of six or more physical drives.
Using a VTrak E310f/s subsystem expanded by four J300s subsystems, your
RAID 50 array supports up to 60 physical drives. See “Configuring JBOD
Expansion” on page 18 or page 24. However, Promise recommends that you set
aside a few physical drives as hot spares. See “Hot Spare Drive(s)” on page 240.
Recommended applications: File and Application Servers, Transaction
Processing, Office applications with many users accessing small files.
RAID 50 Axles
When you create a RAID 50, you must specify the number of
axles
. An axle
refers to a single RAID 5 array that is striped with other RAID 5 arrays to make
RAID 50. An axle can have from 3 to 16 physical drives, depending on the
number of physical drives in the array.
Data
Stripes
Distributed Parity
Disk Drives
Axle 1
Axle 2
Summary of Contents for E310f
Page 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Page 14: ...VTrak E Class Product Manual xiv ...
Page 22: ...VTrak E Class Product Manual 8 ...
Page 58: ...VTrak E Class Product Manual 44 ...
Page 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Page 218: ...VTrak E Class Product Manual 204 ...
Page 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Page 304: ...VTrak E Class Product Manual 290 ...
Page 316: ...VTrak E Class Product Manual 302 ...