Chapter 8: Troubleshooting
269
Physical disk assigned as
dedicated spare
Result of settings or user action. Normal.
Physical disk is no longer
assigned as dedicated
spare
Result of settings or user action. Normal.
Physical disk has been
inserted
A disk drive has been inserted into the VTrak
subsystem.
Physical disk has been
removed
A disk drive has been removed from the VTrak
subsystem.
Bad sector is found on
physical disk
Disk drive has a bad sector. The drive should remap
around the bad sector. If this message appears
repeatedly, replace the disk drive.
Error is detected in remap
sectors
Disk drive has a bad remap sectors. If this message
appears repeatedly, replace the disk drive.
Command times out on
physical drive
Disk drive not responding to commands. If this
message appears repeatedly, replace the disk drive.
Physical disk negotiation
speed is decreased.
Disk drive had to reduce its data rate. If this message
appears repeatedly, replace the disk drive.
Previously configured disk
is no longer found
Disk drive may have failed or was removed from the
enclosure. Replace or reinstall the disk drive as
needed.
A physical disk has
encountered an unknown
(non-ECC) media error.
Disk drive experienced an unknown error. If this
message appears repeatedly, replace the disk drive.
A physical disk has
encountered PFA
condition
A potentially faulty address or bad sector was found.
A configured dead
physical drive has been
inserted
The disk drive inserted into the VTrak was marked as
dead and will not work on the VTrak. Replace the disk
drive.
A physical drive page 0/1
settings have been
changed
Result of settings or user action. Normal.
Physical disk is marked
as dead due to removal/
failure of reassign
sectors/PFA condition/
forced offline state
Replace the disk drive.
Reported Event
Corrective Action
Summary of Contents for E310f
Page 1: ...VTRAK E Class E310f and E310s PRODUCT MANUAL Version 1 1 ...
Page 14: ...VTrak E Class Product Manual xiv ...
Page 22: ...VTrak E Class Product Manual 8 ...
Page 58: ...VTrak E Class Product Manual 44 ...
Page 61: ...Chapter 4 Management with WebPAM PROe 47 Figure 1 The WebPAM PROe log in screen ...
Page 218: ...VTrak E Class Product Manual 204 ...
Page 234: ...VTrak E Class Product Manual 220 Figure 13 Replacing the VTrak controller ...
Page 304: ...VTrak E Class Product Manual 290 ...
Page 316: ...VTrak E Class Product Manual 302 ...