VTrak E-Class Product Manual
18
Configuring JBOD Expansion
To expand the number of disk drives:
1.
On the E310f controller, connect the SAS connector (a subtractive-routed
port) to CN1 (a table-routed port) on the I/O module of the first J300s unit.
See Figure 10.
2.
Connect CN3 (a subtractive-routed port) on the first J300s unit to CN1 on
one of the I/O modules of the next J300s unit.
3.
Connect the remaining J300s units in the same manner.
Figure 10. VTrak E310f JBOD data connections
You can expand a SAN system with no single point of failure. See Figure 11.
Such an arrangement requires:
•
Two Fibre Channel switches
•
Two Fibre Channel HBA cards in each Host PC or Server
•
A network switch (not shown)
•
A network interface card (NIC) in each Host PC or Server
O
I
O
I
Mgmt
UPS
115200
8 N 1
FC 1
FC 2
4
2
1
Gb/s
4
2
1
Gb/s
O
I
SAS Connector
J300s
FC Switch
FC Connector
E310f
CN1
CN3
J300s
CN1