Alarm Output Connection
The illustration below is used as an example. The example used is an alarm.
•
Connect the
ALA
on the I/O terminal interface to the 3.3V or 5V connection on the
external alarm device (Blue wire in illustration)
•
Connect the
ALARM_OUT -
on the I/O terminal interface to the
Input +
connection on the
external alarm device (Red wire in illustration)
•
Connect the
ALARM_GND -
on the I/O terminal interface to the
Input -
connection on the
external alarm device (Black wire in illustration)