VessJBOD 1000 Series Product Manual
26
To view the current settings:
At the cli> prompt, type
cable
and press Enter.
The system returns:
CN#1 Cable Length = 1 meter
CN#2 Cable Length = 1 meter
To set Expansion connector CN2 for a 3-meter cable:
At the cli> prompt, type
cable -a mod -s “cn2=3”
and press Enter.
The system returns:
Cable length of connector 2 is set to 3 meter
Enclosure Command
The Enclosure command:
•
Enables you to reboot the VessJBOD enclosure (below)
•
Displays information about the VessJBOD enclosure (page 27)
•
Enables you to make enclosure settings (page 28)
Rebooting the Controller
You can reboot just the controller (I/O module). This action might be needed to
help with setting changes on the VessJBOD.
To reboot the only the controller:
1.
Verify that no data I/O activity is in progress.
2.
At the cli> prompt, type
enclosure -a mod -s “reboot=1”
and press Enter.
When the cli> prompt reappears, the controller has rebooted.
To reboot the entire JBOD expansion unit:
1.
Verify that no data I/O activity is in progress.
2.
Turn the power supply switch (switches) OFF.
3.
Wait 10 seconds.
4.
Turn the power supply switch (switches) ON.
Caution
A controller reboot does NOT meet the system restart
requirements for a firmware upgrade.