Chapter 4: Management with WebPAM PROe
123
For a list of Migration options and other important information, see “RAID Level
Migration” on page 264.
To Migrate an existing disk array:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Disk Arrays
icon.
3.
Click the Disk Array
icon.
4.
From the dropdown menu the Background Activities tab, choose Start
Migration.
5.
Highlight physical drives you want in the disk array from the Available list and
press the >> button to move them to the Selected list.
You can also double-click them to move them.
The available drives are either HDD or SSD, depending on the type of drives
in the array.
6.
When you are done, click the Next button.
7.
Select a new RAID Level, if desired.
8.
To expand the disk array's capacity, check the Expand Capacity box.
9.
If you checked the Expand Capacity box, enter a number into the Capacity
field and choose the appropriate unit of measure (MB, GB, TB).
10. Under Capacity Usage, highlight the logical drive whose RAID level you want
to change or whose capacity you want to expand.
11. Click the Update button.
The logical drive changes to reflect your choices.
12. Update other logical drives using the same method.
13. When you are done making the changes, click the Next button.
14. Click the Submit button to begin Migration.
To set Migration priority, see “Making Background Activity Settings” on page 56.
Rebuilding a Disk Array
When you rebuild a disk array, you are actually rebuilding the data on a
replacement physical drive.
Notes
•
You can add physical drives to a RAID 50 or RAID 60 array
but you cannot change the number of axles.
•
If you add an odd number of physical drives to a RAID 10
array, it will become a RAID 1E array by default.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...