VessRAID 1000i Series Product Manual
128
may remain intact. You must determine the cause of the problem and correct
it. “Critical & Offline Disk Arrays” on page 302
•
Transport Ready – The result of a successful Prepare for Transport
operation. You remove the physical drives of this logical drive and move
them to another enclosure or to different drive slots in the same enclosure.
After you relocate the physical drives, the logical drive status will show OK.
To create a logical drive, see “Creating a Logical Drive” on page 121.
To delete a logical drive, see “Deleting a Logical Drive” on page 122.
For a Degraded or Offline logical drive, see “Critical & Offline Disk Arrays” on
page 302.
Viewing Logical Drive Information
To view information for a single logical drive:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Disk Arrays
icon.
3.
Click the Disk Array
icon.
4.
Click the Logical Drives
icon
5.
Click the Logical Drive
icon.
To specify an Alias or set the Read and Write Policies, click the Settings tab.
Logical Drive Status
See “Logical Drive Status” on page 127.
Logical Drive Synchronization
Synchronization is an automatic procedure applied to logical drives when they
are created. Yes means the logical drive was synchronized.
Adjustable Items
•
Alias (optional)
•
Read Policy
•
Write Policy
•
Preferred Controller ID
See “Making Logical Drive Settings” on page 129.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...