Setting Temperature Thresholds
To change temperature thresholds:
1.
From the Main Menu, highlight Subsystem Management and press Enter.
2.
Highlight Enclosure Management and press Enter.
3.
Highlight Enclosure Settings and press Enter.
4.
Highlight the Temperature Warning threshold you want to change.
5.
Press the backspace key to erase the current value.
6.
Type a new interval value in degrees C.
7.
Press Ctrl-A to save your settings.
Checking the Batteries
This feature enables you monitor and recondition the subsystem battery or
batteries.
1.
From the Main Menu, highlight Subsystem Management and press Enter.
2.
Highlight Enclosure Management and press Enter.
3.
Highlight Batteries and press Enter.
4.
Highlight the battery you want to monitor and press Enter.
Battery Notes
Each battery works with a controller. If the battery is present in the subsystem but
the corresponding controller is not present, the battery will not appear in the
interface.
If a battery does not reflect normal conditions and it is not currently under
reconditioning, run the Recondition function before you replace the battery. See
“Reconditioning a Battery” on page 153.
Reconditioning fully discharges, then fully recharges the battery. During
reconditioning, if the Adaptive Writeback Cache function is enabled, the controller
cache is set to Write Thru. After reconditioning, the cache is reset to Write Back.
See “Making Controller Settings” on page 147.
If a battery reaches the threshold temperature while charging or discharging, the
charge or discharge pauses and the blower runs at high speed until the battery
temperature falls below the threshold.
If the battery does not maintain normal values after a Recondition, replace the
battery. See “Replacing the Cache Battery” on page 240.
VessRAID automatically reconditions the battery every two months.
When you install a new battery, the cycle count shows 0. VessRAID automatically
runs a recondition on the battery to verify it. If you restart the subsystem or
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...