Chapter 5: Management with the CLU
153
controller before reconditioning is finished, the battery is charged to 100%, then
reconditioning starts again.
Reconditioning a Battery
To recondition the subsystem battery:
1.
From the Main Menu, highlight Subsystem Management and press Enter.
2.
Highlight Enclosure Management and press Enter.
3.
Highlight Batteries and press Enter.
4.
Highlight the battery you want to recondition and press Enter.
5.
Highlight Start Reconditioning and press Enter.
6.
Press Y to confirm.
Reconditioning fully discharges, then fully recharges the battery. During
reconditioning, if the Adaptive Writeback Cache function is enabled, the
controller cache is set to Write Thru. After reconditioning, the cache is reset
to Write Back. See “Making Controller Settings” on page 147.
Locating an Enclosure
This feature helps you identify the physical VessRAID enclosure you are working
with through the CLU.
1.
From the Main Menu, highlight Subsystem Management and press Enter.
2.
Highlight Enclosure Management and press Enter.
3.
Highlight Locate Enclosure and press Enter.
The disk status LEDs and the LEDs on the back of the enclosure blink for
one minute. See the Figures below.
Figure 5. Disk Status LEDs
Disk Status
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...