VessRAID 1000i Series Product Manual
166
The screen jumps to Disk Arrays Summary.
Running PDM
Be sure PDM must be enabled. See “Enabling PDM on a Disk Array” on
page 164.
To run Predictive Data Migration on a disk array:
1.
From the Main Menu, highlight Disk Array Management and press Enter.
2.
Highlight the disk array you want and press Enter.
3.
Highlight Background Activities and press Enter.
4.
Highlight Predictive Data Migration and press Enter.
5.
Specify the source and target physical drives.
The available drives are either HDD or SSD, depending on the type of drives
in the array.
6.
Highlight Start and press Enter.
Running Transition on a Disk Array
Transition is the process of replacing a revertible spare drive that is currently part
of a disk array with an unconfigured physical drive or a non-revertible spare drive.
For more information, see “Transition” on page 273.
In order to run Transition:
•
The spare drive must be Revertible.
•
You must have an unconfigured physical drive of the same or larger capacity,
and the same type, HDD or SSD, to replace the spare drive.
To run Transition on a disk array:
1.
From the Main Menu, highlight Disk Array Management and press Enter.
2.
Highlight the disk array you want and press Enter.
3.
Highlight Background Activities and press Enter.
4.
Highlight Transition and press Enter.
5.
Specify the source and target physical drives.
The available drives are either HDD or SSD, depending on the type of drives
in the array.
6.
Highlight Start and press Enter.
Locating a Disk Array
This feature helps you identify the physical drives assigned to the disk array you
are working with in the CLU.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...