VessRAID 1000i Series Product Manual
170
5.
Highlight Spare Type and press the spacebar to toggle between Dedicated
and Global.
Dedicated means this spare drive can only be used with the specified disk
arrays. Global means this spare drive can be used by any disk array.
6.
If you chose Dedicated, highlight Dedicated to Arrays and press the
backspace key to erase the current value, then type the new value.
Specify the number(s) of the disk array(s) you want to assign your spare.
The current disk arrays are listed in parentheses.
A dedicated spare drive must be the same drive type, HDD or SSD, as the
drives in the assigned array.
7.
Press Ctrl-A to save the spare drive.
Making Spare Drive Settings
To change spare drive settings:
1.
From the Main Menu, highlight Spare Drive Management and press Enter.
A list of the current spare drives appears, including the following parameters:
2.
Highlight the spare drive you want to change and press Enter.
3.
Highlight the setting you want to change:
•
Revertible – A revertible drive can be returned to spare status after you
replace the failed drive in a disk array. See “Transition” on page 273 for
more information.
•
Type – Dedicated means this spare drive can only be used with the
specified disk array(s). Global means this spare drive can be used by
any disk array.
4.
Press the spacebar to toggle between the choices.
5.
For dedicated spares, type the array number the spare is assigned to.
6.
Press Ctrl-A to save your settings.
Running Spare Check
To run Spare Check:
1.
From the Main Menu, highlight Spare Drive Management and press Enter.
A list of the current spare drives appears.
2.
Highlight the spare drive you want to check and press Enter.
3.
Highlight Start Spare Check and press Enter.
The results appear next to Spare Check Status.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...