VessRAID 1000i Series Product Manual
236
Replacing a Power Supply
VessRAID 1700i Series
The power supply on the VessRAID 1700i Series is not replaceable onsite. If you
need to replace the power supply, contact Technical Support and make
arrangements to return the subsystem to Promise for service. See page 319.
VessRAID 1800i Series
The redundant power supplies on the VessRAID 1800i Series are designed as
field-replaceable units. You can replace a power supply without removing the
VessRAID from the rack.
Removing the old power supply
To remove the power supply:
1.
Verify that the power supply LED is amber or red.
2.
Switch off the power to the power supply you plan to replace.
3.
Unplug the power cord.
4.
Loosen and remove the retaining screw on the left side of the power supply.
5.
Pull the power supply out of the VessRAID enclosure.
Installing the new power supply
To install the power supply:
1.
Carefully slide the power supply into the enclosure.
2.
Install and tighten the retaining screw on the left side of the power supply.
3.
Plug in the power cord.
4.
Switch on the power supply.
5.
Verify that the new power supply LED is green.
This completes the power supply replacement procedure.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...