VessRAID 1000i Series Product Manual
238
See page 240 and page 242 for more information.
2.
Carefully slide the new RAID Controller into the enclosure.
3.
Swing the latch to the left and secure it with the thumbscrew.
4.
Reconnect the iSCSI, Ethernet, serial, and power cables.
5.
Switch on the power.
The VessRAID restarts. For more information about VessRAID’s start-up
behavior, see “Connecting the Power” on page 24.
This completes the RAID Controller replacement procedure.
Replacing a Cooling Fan
To replace a fan:
1.
Verify that the Fan LED on the cooling unit is amber or red. See Figure 2.
Figure 2. Fan LEDs
2.
Shut down the VessRAID and remove the RAID Controller.
See “Replacing a RAID Controller” on page 237.
3.
Lay the RAID Controller on a non-static surface and remove the cover
attaching screws, one on each side, then remove the cover.
Cautions
•
Only a qualified technician should perform this procedure.
•
You must shut down the VessRAID subsystem before you
can perform this procedure.
Fan 2 LED
Fan 1 LED
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...