VessRAID 1000i Series Product Manual
240
8.
Reinstall the RAID Controller.
See “Replacing a RAID Controller” on page 237.
This completes the fan replacement procedure.
Replacing the Cache Battery
A cache battery or Battery Backup Unit (BBU) is optional on VessRAID. If your
system has a cache battery, it is located inside the RAID Controller. The battery
assembly is replaced as a unit.
To replace the cache battery:
1.
Verify that the Battery LED is amber or red. See Figure 5.
Figure 5. VessRAID enclosure LEDs
2.
Shut down the VessRAID. See “Shutting Down the Subsystem” on page 91
or page 204.
3.
Shut down the VessRAID and remove the RAID Controller.
See “Replacing a RAID Controller” on page 237.
Cautions
•
Try reconditioning the battery before you replace it. See
page 103 or page 153 for more information.
•
If power service has failed, do not remove the RAID Controller
if the Dirty Cache LED is lighted. See Figure 5. Wait until
power service is restored.
•
Only a qualified technician should perform this procedure.
•
You must shut down the VessRAID subsystem before you
can perform this procedure.
•
Installing the wrong replacement battery can result in an
explosion.
•
Dispose of used batteries according to the instructions that
come with the battery.
Battery LED
Dirty Cache LED
Status LED
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...