Chapter 8: Technology Background
271
At this point, you have the choice of:
•
Format the unpartitioned/unformatted capacity as a second logical drive
•
Delete the existing disk array and create a new one in the desired size
Delete and Recreate
If you require a logical drive larger than the maximum expansion size:
1.
Backup the data from the current logical drive.
2.
Delete the current logical drive.
See page 122 (WebPAM PROe) or page 168 (CLU).
3.
Create a new logical drive with the desired capacity.
See page 121 (WebPAM PROe) or page 167 (CLU).
4.
Restore the data to the new logical drive.
Media Patrol
Media Patrol is a routine maintenance procedure that checks the magnetic media
on each disk drive. Media Patrol checks all physical drives assigned to disk
arrays. Media Patrol does not check unconfigured drives.
Media Patrol will also check spare drives, if those drives have Media Patrol
enabled. Media Patrol for spare drives is enabled by default. You can disable it in
VessRAID’s Command Line Interface (CLI).
Unlike Synchronization and Redundancy Check, Media Patrol is concerned with
the condition of the media itself, not the data recorded on the media. If Media
Patrol encounters a critical error, it triggers PDM if PDM is enabled.
You can run Media Patrol from the subsystem. See “Running Media Patrol” on
page 57 (WebPAM PROe) or page 145 (CLU).
You can also run Media Patrol on a disk array. See “Running Media Patrol on a
Disk Array” on page 124 (WebPAM PROe only).
Current LD Size
Maximum LD
Expansion Size
Sector Size
8 to 16 TB
16 TB
4096 bytes
4 to 8 TB
8 TB
2048 bytes
2 to 4 TB
4 TB
1024 bytes
up to 2 TB
2 TB
512 bytes
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...