VessRAID 1000i Series Product Manual
282
If the Controller Status LED continues to display amber after startup, contact
Promise Technical Support. See page 319.
The Dirty Cache LED flashes during input/output operation. If the LED shines
amber and the power is off, there is unsaved data in the cache. Do NOT power
down the VessRAID while this LED is on. See “Browser Does Not Connect to
WebPAM PROe” on page 314 for more information.
If the battery LED is amber or red, try reconditioning the battery. See
“Reconditioning a Battery” on page 103 or page 153. If the condition returns,
replace the battery.
If the fan LED is amber or red:
1.
Identify the malfunctioning fan. See “Viewing Enclosure Information” on
page 100 or page 150.
2.
Replace the fan. See “Replacing a Cooling Fan” on page 238.
Also see “Enclosure Problems” on page 308.
CLU Reports a Problem
The CLU reports information passively—you must determine which functions to
check based on the sound of the VessRAID’s buzzer and any amber or red
LEDs. See page 277 through 281.
Check the event logs first. Then check the reported component.
Viewing Runtime Events
To display Runtime Events:
1.
From the Main Menu, highlight Event Viewer and press Enter.
The log of Runtime Events appears. Events are added to the top of the list.
Each item includes:
•
Sequence number – Begins with 0 at system startup.
•
Device – Disk Array, Logical Drive, Physical Drive by its ID number.
•
Severity – (lowest to highest) Information, Warning, Minor, Major,
Critical and Fatal
•
Timestamp – Date and time the event happened.
•
Description – A description of the event in plain language.
Press the up and down arrow keys to scroll through the log.
Viewing NVRAM Events
This screen displays a list of and information about 63 most important events
over multiple subsystem startups.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...