VessRAID 1000i Series Product Manual
296
PDM is stopped internally The destination drive was removed or used for a
rebuild.
Physical Disk
Physical disk is marked
online
Disk drive restored to normal operation.
Physical disk is marked
online
Disk drive removed from service due to errors. If
necessary, try to force the disk online. See page 108
(WebPAM PROe) or page 157 (CLU).
Physical disk is marked
as dead.
Disk drive failure. Replace the disk drive.
Physical disk is marked
as dead after it was
removed and reinserted
by the user.
Try forcing the disk online. See page 108 (WebPAM
PROe) or page 157 (CLU)
Physical disk has been
reset
Disk drive reset after error and should function
normally.
Physical disk assigned as
global spare
Result of settings or user action. Normal.
Physical disk is no longer
assigned as global spare
Result of settings or user action. Normal.
Physical disk assigned as
dedicated spare
Result of settings or user action. Normal.
Physical disk is no longer
assigned as dedicated
spare
Result of settings or user action. Normal.
Physical disk has been
inserted
A disk drive has been inserted into the VessRAID
subsystem.
Physical disk has been
removed
A disk drive has been removed from the VessRAID
subsystem.
Bad sector is found on
physical disk
Disk drive has a bad sector. The drive should remap
around the bad sector. If this message appears
repeatedly, replace the disk drive.
Error is detected in remap
sectors
Disk drive has a bad remap sectors. If this message
appears repeatedly, replace the disk drive.
Command times out on
physical drive
Disk drive not responding to commands. If this
message appears repeatedly, replace the disk drive.
Reported Event
Corrective Action
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...