VessRAID 1000i Series Product Manual
298
PSU 12V/5V/3.3V power
is within the range
Normal.
RAID Level Migration
RAID Level migration is
started
Result of settings or user action. Normal.
RAID Level migration is
completed
Normal.
RAID Level migration is
paused
Migration paused because of user intervention,
schedule or a higher priority background activity.
RAID Level migration is
resumed
Migration has resumed again after a pause.
RAID Level migration is
stopped
Migration stopped because of user intervention,
schedule or the logical drive was deleted or went
critical or offline.
RAID Level migration has
encountered a physical
disk error
Bad block found on a disk drive. Migration will finish.
Check the disk drive check table after migration and
replace disk drive as needed.
RAID Level migration is
aborted due to an internal
error.
System resources are low. Reduce system load or
restart the VessRAID. See page 94 (WebPAM PROe)
or page 207 (CLU).
RAID Level migration is
queued
Migration has been set manually or by schedule.
Migration has detected/
cleared stale NV
Watermark
Watermarks are progress markers left as the result of
interrupted RAID migrations. If the watermark was
cleared, migration should finish.
Array was incomplete due
to missing NV Watermark
RAID migration was interrupted by a shutdown.
If array is online, try migration again. See page 122
(WebPAM PROe) or page 165 (CLU).
If array is offline, delete and recreate array. See
page 119 and page 114 (WebPAM PROe) or
page 162 and page 158 (CLU).
Rebuild
Rebuild is started
Result of settings or user action. Normal.
Rebuild is completed
Normal.
Rebuild is paused
Rebuild paused because of user intervention,
schedule or a higher priority background activity.
Reported Event
Corrective Action
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...