Chapter 9: Troubleshooting
299
Rebuild is resumed
Rebuild has resumed again after a pause.
Rebuild is stopped
Rebuild stopped because of user intervention,
schedule or the logical drive was deleted or the target
disk drive encountered an error.
If rebuild stopped by the user, restart the rebuild. See
page 123 (WebPAM PROe) or page 164 (CLU).
Rebuild stopped internally The logical drive is offline. See page 302.
Rebuild is aborted due to
an internal error.
System resources are low. Reduce system load or
restart the VessRAID. See page 94 (WebPAM PROe)
or page 207 (CLU).
Rebuild is queued
Rebuild has been set manually or by schedule.
Rebuild marks logical
drive synchronized upon
rebuild completion
Result of successful rebuild. Normal.
Redundancy Check
Redundancy Check is
started
Redundancy Check has started manually or by
schedule.
Redundancy Check is
completed
Redundancy Check has finished.
Redundancy Check is
paused
Redundancy Check paused because of user
intervention, schedule or a higher priority background
activity.
Redundancy Check is
resumed
Redundancy Check has resumed again after a
pause.
Redundancy Check is
stopped
Redundancy Check stopped because of user
intervention, schedule or the logical drive was deleted
or went critical or offline. See page 302.
Redundancy Check is
aborted due to internal
error
System resources are low. Reduce system load or
restart the VessRAID. See page 94 (WebPAM PROe)
or page 207 (CLU).
Redundancy Check
encountered inconsistent
block(s)
Check the logical drive’s inconsistent block table. See
page 131. Rebuild the disk array if necessary. See
page 114 (WebPAM PROe) or page 158 (CLU).
Redundancy Check task
is queued
Redundancy Check has been set manually or by
schedule.
Redundancy Check task
is stopped internally
The logical drive is offline. See page 302.
Reported Event
Corrective Action
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...