VessRAID 1000i Series Product Manual
306
Physical Drive Problems
Physical Drive Offline
Check the drive for:
•
PFA Condition – Caused by a bad block or sector.
See “Clearing Stale and PFA Conditions” on page 108 (WebPAM PROe) or
page 156 (CLU).
•
Stale Configuration – Caused by obsolete array information on the physical
drive. Identify the disk array to which the physical drive belongs. Then delete
the disk array. See “Deleting a Disk Array” on page 119 (WebPAM PROe) or
page 162 (CLU).
If the error condition remains on the physical drive, clear the error condition.
See “Clearing Stale and PFA Conditions” on page 108 (WebPAM PROe) or
page 156 (CLU).
Physical Drive Not Usable
This condition occurs when you have a missing or defective SAS cable between
the VessRAID subsystem and a VessJBOD enclosure.
Physical Drive Failed
When physical drive status shows failed, the physical drive cannot be repaired.
You must replace the failed drive.
Physical Drive Fails during Migration
VessRAID has two methods for migrating a disk array:
•
DDF – The default setting. Slower but reliable
•
NVRAM – An optional setting that requires special access. Faster but risks
data loss
Normally, RAID level migration is done under the default Disk Data Format (DDF)
setting. If a physical drive or the controller fails during migration, the disk array
goes critical, and you can rebuild it. Migration under DDF can take up to several
hours depending on the number and size of the physical drives and data input/
output activity.
Caution
VessRAID supports disk drive hot-swapping. To avoid hand
contact with an electrical hazard, do not remove more than one
drive carrier a time.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...