VessRAID 1000i Series Product Manual
310
Power Supply
VessRAID 1800i Series
VessRAID 1800i Series has two power supplies. The advantage
of two power supplies is that, should one fail, the other will
continue powering the subsystem. The power supplies are hot-
swappable.
VessRAID 1700i Series
VessRAID 1700i Series has only one power supply and it is not
replaceable onsite. If you need to replace the power supply,
contact Technical Support and make arrangements to return the
subsystem to Promise for service. See page 319.
Fan Failure
As noted above, if a power supply fan fails, you must replace the
power supply. Without the fan to cool it, the power supply will
overheat and eventually fail anyway.
See page 236 for instructions on replacing a power supply.
Battery
VessRAID uses an optional battery as backup power for the
cache. Should a power failure occur, the battery enables the
cache to hold data up to 72 hours. The battery recharges during
normal VessRAID operation.
First, try reconditioning the battery. See page 103 (WebPAM
PROe) or page 153 (CLU).
If the battery does not respond, installing a replacement battery
will correct a marginal or failed condition.
See page 240 for instructions on replacing the battery.
Summary of Contents for VessRAID 1720i
Page 1: ...VessRAID 1720i 1730i 1740i 1820i 1830i 1840i Product Manual Version 1 1 ...
Page 16: ...VessRAID 1000i Series Product Manual xvi ...
Page 114: ...VessRAID 1000i Series Product Manual 98 The changes take effect immediately ...
Page 126: ...VessRAID 1000i Series Product Manual 110 Figure 8 Disk Status LED Disk Status ...
Page 154: ...VessRAID 1000i Series Product Manual 138 ...
Page 165: ...Chapter 5 Management with the CLU 149 Figure 4 Controller Status LED Controller Status ...
Page 226: ...VessRAID 1000i Series Product Manual 210 ...
Page 260: ...VessRAID 1000i Series Product Manual 244 ...