Chapter 4: Management with WebPAM PRO
97
You can also perform a PDM manually under Disk Array Background Activity.
SCSI Management
The SCSI Management–Information tab lists the SCSI Channels for this
subsystem. SCSI Management applies to VTrak 8100, 12100 and 15110.
LUN Settings
The SCSI Management–Console LUN Settings tab enables you make RAID
Console and TID LUN settings. This feature applies to VTrak 8100, 12100 and
15110.
The SCSI RAID Console enables in-band SCSI managment of the VTrak
subsystem. Neither WebPAM PRO nor the Command Line Utility (CLU) provided
with VTrak use in-band SCSI technology.
This feature is for future use. For
now, leave it DISABLED
.
The RAID Console LUN is the Controller's SCSI address. LUN stands for Logical
Unit Number. Essentially it is a subdivision of a SCSI Target ID. The default
setting for the RAID Console is TID 0, LUN 7. This setting is adequate for most
WebPAM and RAID subsystem most configurations. If an address conflict occurs,
you might have to change the Console LUN setting.
You must have Creation Rights to access this function.
To make settings:
1.
Click the Subsystem
icon.
2.
Click on the VTrak
icon.
3.
Click on the SCSI Management
icon.
4.
Click on the Console LUN Settings tab.
5.
Check the Enable LUN Settings box to enable the SCSI RAID Console.
6.
For SCSI Channel 1, in the center column, select the SCSI Target ID number
under which you want to set the Console LUN.
Note
You must enable Media Patrol and PDM on each disk array.
•
LUN Settings (below)
•
TID Settings (page 98)
•
Statistics (page 99)