VTrak 15110 User Manual
172
Logical Drive Management
Logical drives are created under the Disk Array Managment, Disk Array
Properties function. This function enables you can specify names and make
SCSI assignments to existing logical drives.
Name
1.
From the Main menu, press
4
and
Enter
, then press
1
and
Enter
to access
Logical Drive Name.
Please enter your menu choice>1
Enter Logical Drive ID(1, 2)>
If you have multiple logical drives, specify the one you want by its ID number.
Current LD 1 Name: LogDrv1
Enter the new name>Logical Drive A
Name changed to Logical Drive A for LD 1
Press Enter key to return
2.
Type a name for the logical drive and press
Enter
.
3.
Press
Enter
again to return to the Logical Drive Management menu.
SCSI Assignment
Use this feature to change the SCSI LUN assignments for a logical drive. You can
change the Target ID of the logical drive and specify LUNs for each SCSI
channel.
1.
From the Main menu, press
4
and
Enter
, then press
2
and
Enter
to access
SCSI Assignment for channel 1.
Modify TID and LUN for SCSI channel 1, LD 1(y/n)?>
y
2.
Type Y and Enter to confirm.
Enter the new TID (1,2,3)>
3
3.
Type the new TID for iSCSI channel 1 and press
Enter
.
Enter the new LUN (0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15)>
5
4.
Type the new LUN for iSCSI channel 1 and press
Enter
.
LUN is set to 5 for SCSI channel 1 LD 1
Press Enter key to return
5.
Press
Enter
to move to access SCSI Assignment for channel 1
Modify LUN for SCSI channel 2, LD 1(y/n)?>
6.
To make a change, press
Y
and
Enter
.
Make the LUN settings for Channel 2 as needed.
7.
Press
Enter
to return to the Logical Drive Management menu.