Chapter 5: Management with the CLU
185
Available free Physical Drive(s):
1
2
7
Choose the free Physical Drive for rebuilding>
2
Rebuild Disk Array 1 on Physical Drive 2 now(y/n)?>
y
3.
Choose the ID number of a free physical drive to rebuild your logical drive
and press
Enter
.
Press
Y
and
Enter
to confirm.
The Screen returns to the Maintenance menu.
If the Maintenance Activity Monitor is enabled, you can watch the Rebuild
progress on your monitor.
Manual PDM
Preventive Data Migration (PDM) refers to a feature that monitors disk drives and
replaces an unhealthy disk drive before the logical drive goes critical. PDM can
run automatically. See page 169.
PDM for Logical Drive allows you to replace a suspect disk drive manually, while
keeping the disk array functional and available.
1.
Press
4
and
Enter
to use PDM on a disk array.
**************PDM for Disk Array**************
Id
Disk Array Name
Mode
Size
---------------------------------------------------------------
1
Daniels
RAID5
237 GB
2 Kirts
RAID3
107
GB
Select the LD Logical Drive ID for PDM
Press R to return after finished>
2
2.
Choose the ID number of the logical drive for PDM and press
Enter
.
A list of disk array member disks appears beside the prompt.
Enter the unhealthy PD ID(1,5,6)>
6
Enter the spare PD ID(2,3,7)>
7
Start PDM for Logical Drive 1 (y/n)?>
y
3.
Choose the ID number of the unhealthy disk (physical) and press
Enter
.
A list of available spare disks appears beside the prompt.
4.
Choose the ID number of the spare disk (physical drive) and press
Enter
.
5.
Press
Y
and
Enter
to confirm.